Line 1: |
Line 1: |
− | {{Template: Networking_rutos_manual_fw_disclosure | + | {{Template: Networking_device_manual_fw_disclosure |
− | | fw_version = {{#switch: {{{series}}} | + | | series = {{{series}}} |
− | | RUT2XX = {{{series}}}_R_00.01.13 | + | | name = {{{name}}} |
− | | RUT9XX = {{{series}}}_R_00.06.07}}
| + | | fw_version ={{Template: Networking_device_manual_latest_fw |
− | | series = {{{series}}} | + | | series = {{{series}}} |
| + | | name = {{{name}}} |
| + | }} |
| }} | | }} |
| ==Summary== | | ==Summary== |
Line 276: |
Line 278: |
| </tr> | | </tr> |
| <tr> | | <tr> |
− | <td><span style="color: red;">Trigger output:</span> Output</td> | + | <td><span style="color: red;">Trigger output:</span> Output</td>{{#ifeq:{{{name}}}|RUT955| |
− | <td>Open collector output | Relay output | Both; default: <b>Open collector output</b></td> | + | <td>Open collector output {{!}} Relay output {{!}} Both; default: <b>Open collector output</b></td>| |
| + | <td>4PIN output; default: <b>4PIN output</b></td>}} |
| <td>Which output(s) will be triggered.</td> | | <td>Which output(s) will be triggered.</td> |
| </tr> | | </tr> |
Line 332: |
Line 335: |
| This section is used to configure the Modbus RTU master's RS232 serial interface settings. Refer to the figure and table below for information on RS232 configuration. | | This section is used to configure the Modbus RTU master's RS232 serial interface settings. Refer to the figure and table below for information on RS232 configuration. |
| | | |
− | [[File:Networking_rut_manual_modbus_modbus_serial_master_rs232.png|borer|class=tlt-border]] | + | [[File:Networking_rut_manual_modbus_modbus_serial_master_rs232.png|border|class=tlt-border]] |
| | | |
| <table class="nd-mantable"> | | <table class="nd-mantable"> |
Line 467: |
Line 470: |
| </tr> | | </tr> |
| <tr> | | <tr> |
− | <td>Period</td> | + | <td>Frequency settings period</td> |
− | <td>integer [1..9999]; default: <b>10</b></td> | + | <td>Period {{!}} Schedule; default: <b>Period</b></td> |
− | <td>Interval (in minutes) at which requests are sent to the slave device.</td> | + | <td>Specifies whether request frequency should happen every x amount of seconds (<i>Period</i>) or on a set schedule (<i>Schedule</i>).</td> |
| + | </tr> |
| + | <tr> |
| + | <td>Period/Schedule</td> |
| + | <td>integer [1..9999]/; default: <b>10</b></td> |
| + | <td>Interval (in minutes) at which requests are sent to the slave device. Or Shedule (crontab-like, three fields (HH MM SS); e.g.. <i>0,12 * *</i>).</td> |
| </tr> | | </tr> |
| </table> | | </table> |