Text replacement - "\{\{Template: Networking_rutos_manual_fw_disclosure (.*) (.*) (.*) \}\}" to "{{Template: Networking_device_manual_fw_disclosure | series = {{{series}}} | name = {{{name}}} | fw_version ={{Template: Networking_device_manual_latest_fw | series = {{{series}}} | name = {{{name}}} }} }}"
Line 1: Line 1: −
{{Template: Networking_rutos_manual_fw_disclosure
+
{{Template: Networking_device_manual_fw_disclosure
| fw_version ={{Template: Networking_rutos_manual_latest_fw
+
| series = {{{series}}}
 +
| name  = {{{name}}}
 +
| fw_version ={{Template: Networking_device_manual_latest_fw
 
  | series = {{{series}}}
 
  | series = {{{series}}}
 +
| name  = {{{name}}}
 
  }}
 
  }}
 
}}
 
}}
Line 147: Line 150:  
----
 
----
 
A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master. You can create a maximum of 64 request configurations for each slave device.
 
A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master. You can create a maximum of 64 request configurations for each slave device.
 +
 +
<span style="color:red"> <b>Note: </b></span>Modbus TCP Master uses <i>Register Number</i> instead of <i>Register Address</i> for pointing to a register. For example, to request the <i>Uptime</i> of a device, you must use <b>2</b> in the <i>First Register</i> field.
    
The figure below is an example of the Requests configuration section and the table below provides information contained in the fields of that section:
 
The figure below is an example of the Requests configuration section and the table below provides information contained in the fields of that section:
Line 482: Line 487:  
----
 
----
 
A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master.
 
A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master.
 +
 +
<span style="color:red"> <b>Note: </b></span>Modbus Serial Master uses <i>Register Number</i> instead of <i>Register Address</i> for pointing to a register. For example, to request the <i>Uptime</i> of a device, you must use <b>2</b> in the <i>First Register</i> field.
    
The figure below is an example of the Requests configuration section and the table below provides information contained in the fields of that section:
 
The figure below is an example of the Requests configuration section and the table below provides information contained in the fields of that section:
Line 728: Line 735:  
===Request messages===
 
===Request messages===
 
----
 
----
 +
<span style="color:red"> <b>Note: </b></span>MQTT Gateway uses <i>Register Number</i> instead of <i>Register Address</i> for pointing to a register. For example, to request the <i>Uptime</i> of a device, you must use <b>2</b> in the <i>Register Number</i> field.
 +
 
Modbus request data sent in the MQTT payload should be generated in accordance with the following format:
 
Modbus request data sent in the MQTT payload should be generated in accordance with the following format:
  