| A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master. You can create a maximum of 64 request configurations for each slave device. | | A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master. You can create a maximum of 64 request configurations for each slave device. |
| + | |
| + | <span style="color:red"> <b>Note: </b></span> Modbus TCP Master uses <i>Register Number</i> instead of <i>Register Address</i> for pointing to a register. For example, to request the <i>Uptime</i> of a device, you must use <b>2</b> in the <i>First Register</i> field. |
| | | |
| The Request Configuration list is empty by default. To add a new Request Configuration loon to the Add New Instance section. Enter a custom name into the 'Name' field and click the 'Add' button: | | The Request Configuration list is empty by default. To add a new Request Configuration loon to the Add New Instance section. Enter a custom name into the 'Name' field and click the 'Add' button: |
Line 465: |
Line 467: |
| ---- | | ---- |
| A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master. You can create a maximum of 64 request configurations for each slave device. | | A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master. You can create a maximum of 64 request configurations for each slave device. |
| + | |
| + | <span style="color:red"> <b>Note: </b></span> Modbus Serial Master uses <i>Register Number</i> instead of <i>Register Address</i> for pointing to a register. For example, to request the <i>Uptime</i> of a device, you must use <b>2</b> in the <i>First Register</i> field. |
| | | |
| The Request Configuration list is empty by default. To add a new Request Configuration loon to the Add New Instance section. Enter a custom name into the 'Name' field and click the 'Add' button: | | The Request Configuration list is empty by default. To add a new Request Configuration loon to the Add New Instance section. Enter a custom name into the 'Name' field and click the 'Add' button: |
Line 753: |
Line 757: |
| ---- | | ---- |
| A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master. You can create a maximum of 64 request configurations for each slave device. | | A Modbus <b>request</b> is a way of obtaining data from Modbus slaves. The master sends a request to a slave specifying the function code to be performed. The slave then sends the requested data back to the Modbus master. You can create a maximum of 64 request configurations for each slave device. |
| + | |
| + | <span style="color:red"> <b>Note: </b></span> Modbus Serial Master uses <i>Register Number</i> instead of <i>Register Address</i> for pointing to a register. For example, to request the <i>Uptime</i> of a device, you must use <b>2</b> in the <i>First Register</i> field. |
| | | |
| The Request Configuration list is empty by default. To add a new Request Configuration loon to the Add New Instance section. Enter a custom name into the 'Name' field and click the 'Add' button: | | The Request Configuration list is empty by default. To add a new Request Configuration loon to the Add New Instance section. Enter a custom name into the 'Name' field and click the 'Add' button: |
Line 991: |
Line 997: |
| ===Request messages=== | | ===Request messages=== |
| ---- | | ---- |
| + | <span style="color:red"> <b>Note: </b></span>MQTT Gateway uses <i>Register Number</i> instead of <i>Register Address</i> for pointing to a register. For example, to request the <i>Uptime</i> of a device, you must use <b>2</b> in the <i>Register Number</i> field. |
| + | |
| Modbus request data sent in the MQTT payload should be generated in accordance with the following format: | | Modbus request data sent in the MQTT payload should be generated in accordance with the following format: |
| | | |
Line 1,016: |
Line 1,024: |
| <li><b>16</b> - write to multiple holding registers.</li> | | <li><b>16</b> - write to multiple holding registers.</li> |
| </ul></li> | | </ul></li> |
− | <li><b>Register number</b> - number of the first register (in range [1..65536]) from which the registers will be read/written to. | + | <li><b>Register number</b> - number (not address) of the first register (in range [1..65536]) from which the registers will be read/written to. |
| <li><b>Register count/value</b> - this value depends on the Modbus function: | | <li><b>Register count/value</b> - this value depends on the Modbus function: |
| <ul> | | <ul> |