Difference between revisions of "Template:Networking rutos manual modbus modbus tcp get parameters table"

From Teltonika Networks Wiki
Line 582: Line 582:
 
     <tr>
 
     <tr>
 
       <td> LAN IP </td>
 
       <td> LAN IP </td>
       <td>396</td>
+
       <td>394</td>
       <td>397</td>
+
       <td>395</td>
 
       <td>2</td>
 
       <td>2</td>
 
       <td>16 bit unsigned integer</td>
 
       <td>16 bit unsigned integer</td>

Revision as of 14:20, 6 January 2023

Get Parameters


Modbus parameters are held within registers. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes).

The register numbers and corresponding system values are described in the table below:

required value register address register number number of registers representation
System uptime 1 2 2 32 bit unsigned integer
System hostname 7 8 16 Text
Router serial number 39 40 16 Text
LAN MAC address 55 56 16 Text
Router name 71 72 16 Text
Current WAN IP address 139 140 2 8 bit unsigned integer
Digital non-isolated input 324 325 1 16 bit unsigned integer
Digital open collector output 325 326 1 16 bit unsigned integer
PIN 3 direction 326 327 1 16 bit unsigned integer
PIN 4 direction 327 328 1 16 bit unsigned integer
Modem ID 328 329 8 Text
Unix timestamp 364 365 2 32 bit unsigned integer
Local ISO time 366 367 12 Text
UTC time 378 389 12 Text
LAN IP 394 395 2 16 bit unsigned integer