Difference between revisions of "Template:Networking rutos manual modbus modbus tcp get parameters table"

From Teltonika Networks Wiki
(8 intermediate revisions by one other user not shown)
Line 1: Line 1:
 
===Get Parameters===
 
===Get Parameters===
 
----
 
----
Modbus parameters are held within <b>registers</b>. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). The register numbers and corresponding system values are described in the table below:
+
Modbus parameters are held within <b>registers</b>. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes).  
 +
{{#ifeq:{{{name}}}|RUTX12|<br><br>To get data from the second modem, you need to execute this command:
 +
 
 +
$  modbus write -D {{#ifeq:{{{series}}}|TRB14X|192.168.2.1|192.168.1.1}} %MW328  12589 12590 12800
 +
 
 +
This command sets it to primary modem:
 +
 
 +
$ modbus write -D {{#ifeq:{{{series}}}|TRB14X|192.168.2.1|192.168.1.1}} %MW328  13101 12544
 +
 
 +
}}
 +
The register numbers and corresponding system values are described in the table below:
 
<br> <br>
 
<br> <br>
 
<table class="nd-othertables">
 
<table class="nd-othertables">
Line 102: Line 112:
 
     </tr>
 
     </tr>
 
}}
 
}}
{{#ifeq:{{{name}}}|RUT955|
+
{{#switch:{{{name}}}
 +
| RUT955|RUT956=
 
     <tr>
 
     <tr>
 
       <td>Digital input (DIN1) state</td>
 
       <td>Digital input (DIN1) state</td>
Line 126: Line 137:
 
{{#ifeq:{{{analog}}}| 1|
 
{{#ifeq:{{{analog}}}| 1|
 
     <tr>
 
     <tr>
       <td>Analog input (PIN {{#switch:{{{series}}}|TRB2=11|RUT9=9|TRB1=7}}) value</td>
+
       <td>Analog input (PIN {{#switch:{{{series}}}|TRB2=11|RUT9|RUT9M=9|TRB1=7}}) value</td>
 
       <td>141</td>
 
       <td>141</td>
 
         <td>142</td>   
 
         <td>142</td>   
Line 295: Line 306:
 
{{#ifeq:{{{name}}}|RUTX12| |
 
{{#ifeq:{{{name}}}|RUTX12| |
 
{{#switch:{{{series}}}
 
{{#switch:{{{series}}}
| TRB1|RUT36X|RUT2=
+
| TRB1|TRB5=|RUT36X|RUT2=
 
| #default =
 
| #default =
 
       <tr>
 
       <tr>
Line 418: Line 429:
 
|
 
|
 
     <tr>
 
     <tr>
       <td>Digital non-isolated input (4 PIN connector)</td>
+
       <td>Digital non-isolated input {{#ifeq:{{{name}}}|TRB141|(4 PIN connector)|}}</td>
 
       <td>324</td>
 
       <td>324</td>
 
       <td>325</td>
 
       <td>325</td>
Line 425: Line 436:
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
       <td>Digital open collector output (4 PIN connector)</td>
+
       <td>Digital open collector output {{#ifeq:{{{name}}}|TRB141|(4 PIN connector)|}}</td>
 
       <td>325</td>
 
       <td>325</td>
 
       <td>326</td>
 
       <td>326</td>
Line 434: Line 445:
 
{{#switch:{{{series}}}
 
{{#switch:{{{series}}}
 
|TCR1=
 
|TCR1=
|RUTX|TRB2|RUT9|RUT2|RUT2M=
+
|RUTX|TRB2|RUT9|RUT9M|RUT2|RUT2M=
 
|
 
|
 
     <tr>
 
     <tr>
       <td> PIN 3 direction{{#ifeq:{{{name}}}|TRB141| (4 PIN connector)|}}</td>
+
       <td> PIN 3 direction {{#ifeq:{{{name}}}|TRB141|(4 PIN connector)|}}</td>
 
       <td>326</td>
 
       <td>326</td>
 
       <td>327</td>
 
       <td>327</td>
Line 444: Line 455:
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
       <td> PIN 4 direction{{#ifeq:{{{name}}}|TRB141| (4 PIN connector)|}}</td>
+
       <td> PIN 4 direction {{#ifeq:{{{name}}}|TRB141|(4 PIN connector)|}}</td>
 
       <td>327</td>
 
       <td>327</td>
 
       <td>328</td>
 
       <td>328</td>
Line 569: Line 580:
 
       <td>Text</td>
 
       <td>Text</td>
 
   </tr>
 
   </tr>
 +
    <tr>
 +
      <td> LAN IP </td>
 +
      <td>394</td>
 +
      <td>395</td>
 +
      <td>2</td>
 +
      <td>8 bit unsigned integer</td>
 +
  </tr>{{#ifeq:{{{mobile}}}|1|
 +
    <tr>
 +
      <td> Add SMS </td>
 +
      <td>397</td>
 +
      <td>398</td>
 +
      <td>90</td>
 +
      <td>Text</td>
 +
  </tr>
 +
}}
 
</table>
 
</table>

Revision as of 09:56, 27 January 2023

Get Parameters


Modbus parameters are held within registers. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes).

The register numbers and corresponding system values are described in the table below:

required value register address register number number of registers representation
System uptime 1 2 2 32 bit unsigned integer
System hostname 7 8 16 Text
Router serial number 39 40 16 Text
LAN MAC address 55 56 16 Text
Router name 71 72 16 Text
Current WAN IP address 139 140 2 8 bit unsigned integer
Digital non-isolated input 324 325 1 16 bit unsigned integer
Digital open collector output 325 326 1 16 bit unsigned integer
PIN 3 direction 326 327 1 16 bit unsigned integer
PIN 4 direction 327 328 1 16 bit unsigned integer
Modem ID 328 329 8 Text
Unix timestamp 364 365 2 32 bit unsigned integer
Local ISO time 366 367 12 Text
UTC time 378 389 12 Text
LAN IP 394 395 2 8 bit unsigned integer