Difference between revisions of "Template:Networking rutos manual modbus modbus tcp get parameters table"
From Teltonika Networks Wiki
Gytispieze (talk | contribs) |
|||
(7 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
===Get Parameters=== | ===Get Parameters=== | ||
---- | ---- | ||
− | Modbus parameters are held within <b>registers</b>. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). The register numbers and corresponding system values are described in the table below: | + | Modbus parameters are held within <b>registers</b>. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). |
+ | {{#ifeq:{{{name}}}|RUTX12|<br><br>To get data from the second modem, you need to execute this command: | ||
+ | |||
+ | $ modbus write -D {{#ifeq:{{{series}}}|TRB14X|192.168.2.1|192.168.1.1}} %MW328 12589 12590 12800 | ||
+ | |||
+ | This command sets it to primary modem: | ||
+ | |||
+ | $ modbus write -D {{#ifeq:{{{series}}}|TRB14X|192.168.2.1|192.168.1.1}} %MW328 13101 12544 | ||
+ | |||
+ | }} | ||
+ | The register numbers and corresponding system values are described in the table below: | ||
<br> <br> | <br> <br> | ||
<table class="nd-othertables"> | <table class="nd-othertables"> | ||
Line 102: | Line 112: | ||
</tr> | </tr> | ||
}} | }} | ||
− | {{# | + | {{#switch:{{{name}}} |
+ | | RUT955|RUT956= | ||
<tr> | <tr> | ||
<td>Digital input (DIN1) state</td> | <td>Digital input (DIN1) state</td> | ||
Line 126: | Line 137: | ||
{{#ifeq:{{{analog}}}| 1| | {{#ifeq:{{{analog}}}| 1| | ||
<tr> | <tr> | ||
− | <td>Analog input (PIN {{#switch:{{{series}}}|TRB2=11|RUT9=9|TRB1=7}}) value</td> | + | <td>Analog input (PIN {{#switch:{{{series}}}|TRB2=11|RUT9|RUT9M=9|TRB1=7}}) value</td> |
<td>141</td> | <td>141</td> | ||
<td>142</td> | <td>142</td> | ||
Line 295: | Line 306: | ||
{{#ifeq:{{{name}}}|RUTX12| | | {{#ifeq:{{{name}}}|RUTX12| | | ||
{{#switch:{{{series}}} | {{#switch:{{{series}}} | ||
− | | TRB1|RUT36X|RUT2= | + | | TRB1|TRB5=|RUT36X|RUT2= |
| #default = | | #default = | ||
<tr> | <tr> | ||
Line 434: | Line 445: | ||
{{#switch:{{{series}}} | {{#switch:{{{series}}} | ||
|TCR1= | |TCR1= | ||
− | |RUTX|TRB2|RUT9|RUT2|RUT2M= | + | |RUTX|TRB2|RUT9|RUT9M|RUT2|RUT2M= |
| | | | ||
<tr> | <tr> | ||
Line 569: | Line 580: | ||
<td>Text</td> | <td>Text</td> | ||
</tr> | </tr> | ||
+ | <tr> | ||
+ | <td> LAN IP </td> | ||
+ | <td>394</td> | ||
+ | <td>395</td> | ||
+ | <td>2</td> | ||
+ | <td>8 bit unsigned integer</td> | ||
+ | </tr>{{#ifeq:{{{mobile}}}|1| | ||
+ | <tr> | ||
+ | <td> Add SMS </td> | ||
+ | <td>397</td> | ||
+ | <td>398</td> | ||
+ | <td>90</td> | ||
+ | <td>Text</td> | ||
+ | </tr> | ||
+ | }} | ||
</table> | </table> |
Revision as of 09:56, 27 January 2023
Get Parameters
Modbus parameters are held within registers. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes).
The register numbers and corresponding system values are described in the table below:
required value | register address | register number | number of registers | representation |
---|---|---|---|---|
System uptime | 1 | 2 | 2 | 32 bit unsigned integer |
System hostname | 7 | 8 | 16 | Text |
Router serial number | 39 | 40 | 16 | Text |
LAN MAC address | 55 | 56 | 16 | Text |
Router name | 71 | 72 | 16 | Text |
Current WAN IP address | 139 | 140 | 2 | 8 bit unsigned integer |
Digital non-isolated input | 324 | 325 | 1 | 16 bit unsigned integer |
Digital open collector output | 325 | 326 | 1 | 16 bit unsigned integer |
PIN 3 direction | 326 | 327 | 1 | 16 bit unsigned integer |
PIN 4 direction | 327 | 328 | 1 | 16 bit unsigned integer |
Modem ID | 328 | 329 | 8 | Text |
Unix timestamp | 364 | 365 | 2 | 32 bit unsigned integer |
Local ISO time | 366 | 367 | 12 | Text |
UTC time | 378 | 389 | 12 | Text |
LAN IP | 394 | 395 | 2 | 8 bit unsigned integer |