Difference between revisions of "Template:Networking rutos manual modbus modbus tcp get parameters table"

From Teltonika Networks Wiki
Line 184: Line 184:
 
     </tr>
 
     </tr>
 
}}
 
}}
{{#ifeq:{{{mobile}}}| 1|
+
{{#ifeq:{{{mobile}}}|1|{{#ifeq:{{{series}}}|TRB5||
 
     <tr>
 
     <tr>
 
       <td>Mobile data received today (SIM1)</td>
 
       <td>Mobile data received today (SIM1)</td>
Line 200: Line 200:
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
       <td>Mobile data received this week (SIM1)</td>
+
       <td>Mobile data received this week (SIM1)</td>
 
       <td>189</td>
 
       <td>189</td>
 
       <td>190</td>
 
       <td>190</td>
Line 207: Line 207:
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
       <td>Mobile data sent this week (SIM1)</td>
+
       <td>Mobile data sent this week (SIM1)</td>
 
       <td>191</td>
 
       <td>191</td>
 
       <td>192</td>
 
       <td>192</td>
Line 214: Line 214:
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
       <td>Mobile data received this month (SIM1)</td>
+
       <td>Mobile data received this month (SIM1)</td>
 
       <td>193</td>
 
       <td>193</td>
 
       <td>194</td>
 
       <td>194</td>
Line 221: Line 221:
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
       <td>Mobile data sent this month (SIM1)</td>
+
       <td>Mobile data sent this month (SIM1)</td>
 
       <td>195</td>
 
       <td>195</td>
 
       <td>196</td>
 
       <td>196</td>
Line 228: Line 228:
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Mobile data received last 24h (SIM1)</td>
+
         <td>Mobile data received last 24h (SIM1)</td>
 
         <td>197</td>
 
         <td>197</td>
 
         <td>198</td>
 
         <td>198</td>
Line 235: Line 235:
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Mobile data sent last 24h (SIM1)</td>
+
         <td>Mobile data sent last 24h (SIM1)</td>
 
         <td>199</td>
 
         <td>199</td>
 
         <td>200</td>
 
         <td>200</td>
 
         <td>2</td>
 
         <td>2</td>
 
         <td>32 bit unsigned integer</td>
 
         <td>32 bit unsigned integer</td>
     </tr>
+
     </tr>}}|}}
 
{{#ifeq:{{{name}}}|RUT955|
 
{{#ifeq:{{{name}}}|RUT955|
 
       <tr>
 
       <tr>
Line 256: Line 256:
 
         <td>16 bit unsigned integer</td>
 
         <td>16 bit unsigned integer</td>
 
       </tr>|}}
 
       </tr>|}}
{{#ifeq:{{{dualsim}}}| 1|
+
{{#ifeq:{{{mobile}}}|1|{{#ifeq:{{{dualsim}}}| 1|
 
       <tr>
 
       <tr>
 
         <td>Active SIM card</td>
 
         <td>Active SIM card</td>
Line 264: Line 264:
 
         <td>16 bit unsigned integer</td>
 
         <td>16 bit unsigned integer</td>
 
       </tr>
 
       </tr>
}}
+
}}{{#ifeq:{{{series}}}|TRB5||
 
       <tr>
 
       <tr>
 
         <td>Mobile data received last week (SIM1)</td>
 
         <td>Mobile data received last week (SIM1)</td>
Line 292: Line 292:
 
         <td>2</td>
 
         <td>2</td>
 
         <td>32 bit unsigned integer</td>
 
         <td>32 bit unsigned integer</td>
       </tr>
+
       </tr>}}
 
{{#ifeq:{{{name}}}|RUTX12| |
 
{{#ifeq:{{{name}}}|RUTX12| |
 
{{#switch:{{{series}}}
 
{{#switch:{{{series}}}
Line 401: Line 401:
 
       <td>16 bit unsigned integer</td>
 
       <td>16 bit unsigned integer</td>
 
     </tr>
 
     </tr>
|TRB140|TRB141|TRB142|TRB145|RUT300|RUT360=
+
|TRB140|TRB141|TRB142|TRB143|TRB145|RUT300|RUT360|TRB500=
 
     <tr>
 
     <tr>
 
       <td>PIN 3 status (4 PIN connector)</td>
 
       <td>PIN 3 status (4 PIN connector)</td>
Line 437: Line 437:
 
|
 
|
 
     <tr>
 
     <tr>
       <td> PIN 3 direction {{#ifeq:{{{series}}}|TRB1|(4 PIN connector)}}</td>
+
       <td> PIN 3 direction{{#ifeq:{{{name}}}|TRB141| (4 PIN connector)|}}</td>
 
       <td>326</td>
 
       <td>326</td>
 
       <td>327</td>
 
       <td>327</td>
Line 444: Line 444:
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
       <td> PIN 4 direction {{#ifeq:{{{series}}}|TRB1|(4 PIN connector)}} </td>
+
       <td> PIN 4 direction{{#ifeq:{{{name}}}|TRB141| (4 PIN connector)|}}</td>
 
       <td>327</td>
 
       <td>327</td>
 
       <td>328</td>
 
       <td>328</td>

Revision as of 14:03, 1 September 2022

Get Parameters


Modbus parameters are held within registers. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). The register numbers and corresponding system values are described in the table below:

required value register address register number number of registers representation
System uptime 1 2 2 32 bit unsigned integer
System hostname 7 8 16 Text
Router serial number 39 40 16 Text
LAN MAC address 55 56 16 Text
Router name 71 72 16 Text
Current WAN IP address 139 140 2 8 bit unsigned integer
Digital non-isolated input (4 PIN connector) 324 325 1 16 bit unsigned integer
Digital open collector output (4 PIN connector) 325 326 1 16 bit unsigned integer
PIN 3 direction 326 327 1 16 bit unsigned integer
PIN 4 direction 327 328 1 16 bit unsigned integer
Modem ID 328 329 8 Text
Unix timestamp 364 365 2 32 bit unsigned integer
Local ISO time 366 367 12 Text
UTC time 378 389 12 Text