Difference between revisions of "Template:Networking rutos manual modbus modbus tcp set parameters table"
From Teltonika Networks Wiki
Gytispieze (talk | contribs) |
Gytispieze (talk | contribs) |
||
Line 60: | Line 60: | ||
<li>1 - switch to SIM1</li> | <li>1 - switch to SIM1</li> | ||
<li>2 - switch to SIM2</li> | <li>2 - switch to SIM2</li> | ||
− | + | <li>0 - switch from the the SIM card opposite of the one currently in use (SIM1 → SIM2 or SIM2 → SIM1)</li> | |
</ul> | </ul> | ||
</td> | </td> | ||
Line 152: | Line 152: | ||
<td>1{{!}}0</td> | <td>1{{!}}0</td> | ||
<td>Switches PIN 2 state to 0 (dry) / 1 (wet)</td> | <td>Switches PIN 2 state to 0 (dry) / 1 (wet)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td> Switch ACL activity </td> | ||
+ | <td>345</td> | ||
+ | <td>1{{!}}0</td> | ||
+ | <td>Turns ACL activity ON or OFF</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td> Switch ACL ON/OFF </td> | <td> Switch ACL ON/OFF </td> | ||
− | <td> | + | <td>346</td> |
<td>1{{!}}0</td> | <td>1{{!}}0</td> | ||
<td>Turns ACL functionality ON or OFF</td> | <td>Turns ACL functionality ON or OFF</td> |
Revision as of 10:38, 2 December 2021
Set Parameters
The Modbus daemon can also set some device parameters.
value to set | register address | register value | description |
---|---|---|---|
Hostname | 7 | Hostname (in decimal form) | Changes hostname |
Device name | 71 | Device name (in decimal form) | Changes device name |
Reboot | 206 | 1 | Reboots the router |
Switch PIN 3 state | 324 | 1|0 | Toggles PIN 3 ON or OFF, when output is selected |
Switch PIN 4 state | 325 | 1|0 | Toggles PIN 4 ON or OFF, when output is selected |
Switch PIN 3 direction | 324 | 1|0 | Toggles PIN 3 direction between INPUT (0) or OUTPUT (1) |
Switch PIN 4 direction | 325 | 1|0 | Toggles PIN 4 direction between INPUT (0) or OUTPUT (1) |