Set Parameters
The Modbus daemon can also set some device parameters.
value to set | register address | register value | description |
---|---|---|---|
Hostname | 7 | Hostname (in decimal form) | Changes hostname |
Device name | 71 | Device name (in decimal form) | Changes device name |
Reboot | 206 | 1 | Reboots the router |
Switch PIN 3 state | 324 | 1|0 | Toggles PIN 3 ON or OFF, when output is selected |
Switch PIN 4 state | 325 | 1|0 | Toggles PIN 4 ON or OFF, when output is selected |
Switch PIN 3 direction | 324 | 1|0 | Toggles PIN 3 direction between INPUT (0) or OUTPUT (1) |
Switch PIN 4 direction | 325 | 1|0 | Toggles PIN 4 direction between INPUT (0) or OUTPUT (1) |