Line 10: Line 10:     
This manual page provides an overview of the RS232 page in {{{name}}} devices.
 
This manual page provides an overview of the RS232 page in {{{name}}} devices.
{{#ifeq:{{{series}}}|TRB14X|
+
{{#ifeq: {{{series}}} | TRB1 |
 
==General information==
 
==General information==
   Line 83: Line 83:  
The <b>RS232 Configuration</b> section is used to set up the main operating parameters and the serial type of the RS232 connector.
 
The <b>RS232 Configuration</b> section is used to set up the main operating parameters and the serial type of the RS232 connector.
   −
[[File:Networking_rutos_manual_rs232_rs232_configuration.png|border|class=tlt-border]]
+
[[File:Networking_rutos_manual_rs232_rs232_configuration_data_bits_{{{data_bits}}}.png|border|class=tlt-border]]
    
<table class="nd-mantable">
 
<table class="nd-mantable">
Line 98: Line 98:  
     <tr>
 
     <tr>
 
     <td>Baud rate</td>
 
     <td>Baud rate</td>
         <td>300 | {{#ifeq:{{{series}}}|TRB2XX|600 <nowiki>|</nowiki> |}}1200 | 2400 | 4800 | 9600 | 19200 | 38400 | 57600 | 115200{{#ifeq:{{{series}}}|TRB2XX| <nowiki>|</nowiki> 230400 <nowiki>|</nowiki> 460800 <nowiki>|</nowiki> 921600 <nowiki>|</nowiki> 1000000 <nowiki>|</nowiki>|}} 3000000; default: <b>{{#ifeq:{{{series}}}|TRB2XX|300|115200}}</b></td>
+
         <td>300 | {{#ifeq:{{{series}}}|TRB2|600 <nowiki>|</nowiki> |}}1200 | 2400 | 4800 | 9600 | 19200 | 38400 | 57600 | 115200{{#ifeq:{{{series}}}|TRB2| <nowiki>|</nowiki> 230400 <nowiki>|</nowiki> 460800 <nowiki>|</nowiki> 921600 <nowiki>|</nowiki> 1000000 <nowiki>|</nowiki>|}} 3000000; default: <b>{{#ifeq:{{{series}}}|TRB2|300|115200}}</b></td>
 
         <td>Data rate for serial data transmission (in bits per second).</td>
 
         <td>Data rate for serial data transmission (in bits per second).</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
     <td>Data bits</td>
 
     <td>Data bits</td>
         <td>{{#ifeq:{{{series}}}|TRB14X|5 <nowiki>|</nowiki> 6 <nowiki>|</nowiki> |}}7 | 8; default: <b>{{#ifeq:{{{series}}}|TRB2XX|7|8}}</b></td>
+
         <td>{{#ifeq:{{{series}}}|TRB1|5 <nowiki>|</nowiki> 6 <nowiki>|</nowiki> |}}7 | 8; default: <b>{{{data_bits}}}</b></td>
 
         <td>Number of data bits for each character.</td>
 
         <td>Number of data bits for each character.</td>
 
     </tr>
 
     </tr>
Line 219: Line 219:  
The <b>Modbus gateway</b> serial type allows redirecting TCP data coming to a specified port to an RTU specified by the Slave ID. The Slave ID can be specified by the user or be obtained directly from the Modbus header.
 
The <b>Modbus gateway</b> serial type allows redirecting TCP data coming to a specified port to an RTU specified by the Slave ID. The Slave ID can be specified by the user or be obtained directly from the Modbus header.
   −
[[File:Networking_rutos_manual_rs485_rs485_configuration_modbus_gateway.png|border|class=tlt-border]]
+
[[File:Networking_rutos_manual_usb_tools_printer_server_usb_to_serial_modbus_gateway.png|border|class=tlt-border]]
    
<table class="nd-mantable">
 
<table class="nd-mantable">