Changes

no edit summary
Line 91: Line 91:  
     </tr>}}
 
     </tr>}}
 
</table>
 
</table>
}}
      
==Cables==
 
==Cables==
Line 106: Line 105:     
[[File:Straight cable pinout v2.png|400px]]
 
[[File:Straight cable pinout v2.png|400px]]
 +
 
----
 
----
   Line 115: Line 115:     
[[File:Straight crossed rs232 cable pinout v2.png|400px]]
 
[[File:Straight crossed rs232 cable pinout v2.png|400px]]
 +
 
----
 
----
    
Maximum cable length is 15 meters or the cable length equal to a capacitance of 2500 pF (for a 19200 baud rate). Using lower capacitance cables can increase the distance. Reducing communication speed can also increase maximum cable length.|}}
 
Maximum cable length is 15 meters or the cable length equal to a capacitance of 2500 pF (for a 19200 baud rate). Using lower capacitance cables can increase the distance. Reducing communication speed can also increase maximum cable length.|}}
 +
 
==RS232 Configuration==
 
==RS232 Configuration==
   Line 243: Line 245:  
         <td>0 {{!}} 1; default: <b>0</b></td>
 
         <td>0 {{!}} 1; default: <b>0</b></td>
 
         <td>Default output state value, when the application is started.</td>
 
         <td>Default output state value, when the application is started.</td>
     </tr>
+
     </tr><!--
 
     <tr>
 
     <tr>
 
     <td><span style="color: red;">Server settings</span> | <span style="color: green;">UDP</span>: Number of clients</td>
 
     <td><span style="color: red;">Server settings</span> | <span style="color: green;">UDP</span>: Number of clients</td>
Line 268: Line 270:  
         <td>port; default: <b>none</b></td>
 
         <td>port; default: <b>none</b></td>
 
         <td>Specifies port number for predefined connection 2.</td>
 
         <td>Specifies port number for predefined connection 2.</td>
     </tr>
+
     </tr>-->
 
     <tr>
 
     <tr>
 
       <td><span style="color: purple;">Client settings</span>: Server Address</td>
 
       <td><span style="color: purple;">Client settings</span>: Server Address</td>
Line 293: Line 295:  
         <td>off | on; default: <b>off</b></td>
 
         <td>off | on; default: <b>off</b></td>
 
         <td>Turns RS232 echo on or off. RS232 echo is a loopback test usually used to check whether the RS232 cable is working properly.</td>
 
         <td>Turns RS232 echo on or off. RS232 echo is a loopback test usually used to check whether the RS232 cable is working properly.</td>
     </tr>
+
     </tr><!--
 
     <tr>
 
     <tr>
 
     <td><span style="color: red;">Server settings</span> | <span style="color: blue;">TCP</span>: Max clients</td>
 
     <td><span style="color: red;">Server settings</span> | <span style="color: blue;">TCP</span>: Max clients</td>
Line 323: Line 325:  
         <td>off | on; default: <b>off</b></td>
 
         <td>off | on; default: <b>off</b></td>
 
         <td>When enabled, a new TCP connection will be made after sending every data package.</td>
 
         <td>When enabled, a new TCP connection will be made after sending every data package.</td>
     </tr>
+
     </tr>-->
 
</table>
 