Difference between revisions of "Template:Networking tcr100 manual power consumption table"

From Teltonika Networks Wiki
(Created page with "<table class="nd-othertables_3"> <tr style="font-weight:bold"> <th width=800>Test type</th> <th width=150>Current (mA)</span></th> <th width=150>Pow...")
(No difference)

Revision as of 10:56, 8 February 2022

Test type Current (mA) Power consumption (W)
Idle, no SIM card inserted (9 V) 170 1.53
Idle, no SIM card inserted (12 V) 135 1.62
Idle, no SIM card inserted (24 V) 69 1.65


Test type Current (mA) Power consumption (W)
Idle + mobile data on (9 V) 208 1.87
Idle + mobile data on (12 V) 158 1.90
Idle + mobile data on (24 V) 91 2.18


Test type Current (mA) Power consumption (W)
1 LAN device connected + mobile data on (9 V) 254 2.29
1 LAN device connected + mobile data on (12 V) 195 2.34
1 LAN device connected + mobile data on (24 V) 108 2.59


Test type Current (mA) Power consumption (W)
High CPU load + max speed LTE transmission + 2 LAN devices connected + data transfer via WiFi (9 V) 653 5.88
High CPU load + max speed LTE transmission + 2 LAN devices connected + data transfer via WiFi (12 V) 495 5.94
High CPU load + max speed LTE transmission + 2 LAN devices connected + data transfer via WiFi (24 V) 257 6.17