Difference between revisions of "Template:Networking trb143 faq power consumption table"

From Teltonika Networks Wiki
(Created page with "<table class="nd-othertables_3"> <tr style="font-weight:bold"> <th width=800>Test type</th> <th width=150>Current (mA)</span></th> <th width=150>Pow...")
 
 
(2 intermediate revisions by the same user not shown)
Line 2: Line 2:
 
     <tr style="font-weight:bold">
 
     <tr style="font-weight:bold">
 
         <th width=800>Test type</th>
 
         <th width=800>Test type</th>
       <th width=150>Current (mA)</span></th>
+
       <th width=150><center>Current (mA)</span></center></th>
       <th width=150>Power consumption (W)</th>
+
       <th width=170><center>Power consumption (W)</center></th>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>Idle, no SIM card inserted (9 V)</td>
 
         <td>Idle, no SIM card inserted (9 V)</td>
       <td><b>210</b></td>
+
       <td><center><b>94</b></center></td>
       <td><b>1.89</b></td>
+
       <td><center><b>0.85</b></center></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>Idle, no SIM card inserted (12 V)</td>
 
         <td>Idle, no SIM card inserted (12 V)</td>
       <td><b>180</b></td>
+
       <td><center><b>97</b></center></td>
       <td><b>2.16</b></td>
+
       <td><center><b>1.16</b></center></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>Idle, no SIM card inserted (24 V)</td>
 
         <td>Idle, no SIM card inserted (24 V)</td>
       <td><b>90</b></td>
+
       <td><center><b>68</b></center></td>
       <td><b>2.16</b></td>
+
       <td><center><b>1.63</b></center></td>
 
     </tr>
 
     </tr>
 
</table>
 
</table>
Line 26: Line 26:
 
     <tr style="font-weight:bold">
 
     <tr style="font-weight:bold">
 
         <th width=800>Test type</th>
 
         <th width=800>Test type</th>
       <th width=150>Current (mA)</span></th>
+
       <th width=150><center>Current (mA)</span></center></th>
       <th width=150>Power consumption (W)</th>
+
       <th width=170><center>Power consumption (W)</center></th>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>Idle + mobile data on <sup><small>1</small></sup> (9 V)</td>
 
         <td>Idle + mobile data on <sup><small>1</small></sup> (9 V)</td>
       <td><b>280</b></td>
+
       <td><center><b>99</b></center></td>
       <td><b>2.52</b></td>
+
       <td><center><b>0.89</b></center></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>Idle + mobile data on <sup><small>1</small></sup> (12 V)</td>
 
         <td>Idle + mobile data on <sup><small>1</small></sup> (12 V)</td>
       <td><b>230</b></td>
+
       <td><center><b>112</b></center></td>
       <td><b>2.76</b></td>
+
       <td><center><b>1.34</b></center></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
 
         <td>Idle + mobile data on <sup><small>1</small></sup> (24 V)</td>
 
         <td>Idle + mobile data on <sup><small>1</small></sup> (24 V)</td>
       <td><b>110</b></td>
+
       <td><center><b>74</b></center></td>
       <td><b>2.64</b></td>
+
       <td><center><b>1.78</b></center></td>
 
     </tr>
 
     </tr>
 
</table>
 
</table>
Line 50: Line 50:
 
     <tr style="font-weight:bold">
 
     <tr style="font-weight:bold">
 
         <th width=800>Test type</th>
 
         <th width=800>Test type</th>
       <th width=150>Current (mA)</span></th>
+
       <th width=150><center>Current (mA)</span></th>
       <th width=150>Power consumption (W)</th>
+
       <th width=170><center>Power consumption (W)</th>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Max speed LTE transmission + 1 LAN device connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> + M-Bus (Data to Server) (9V)</td>
+
         <td>Mobile data on <sup><small>1</small></sup> + 1 LAN device connected <sup><small>2</small></sup> (9 V)</td>
       <td><b>510</b></td>
+
       <td><center><b>152</b></td>
       <td><b>4.59</b></td>
+
       <td><center><b>1.37</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Max speed LTE transmission + 1 LAN device connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> + M-Bus (Data to Server) (12 V)</td>
+
         <td>Mobile data on <sup><small>1</small></sup> + 1 LAN device connected <sup><small>2</small></sup> (12 V)</td>
       <td><b>410</b></td>
+
       <td><center><b>135</b></td>
       <td><b>4.92</b></td>
+
       <td><center><b>1.62</b></td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Max speed LTE transmission + 1 LAN device connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> + M-Bus (Data to Server) (24 V)</td>
+
         <td>Mobile data on <sup><small>1</small></sup> + 1 LAN device connected <sup><small>2</small></sup> (24 V)</td>
       <td><b>220</b></td>
+
       <td><center><b>103</b></td>
       <td><b>5.28</b></td>
+
       <td><center><b>2.47</b></td>
 
     </tr>
 
     </tr>
 
</table>
 
</table>
  
 +
 +
<table class="nd-othertables_3">
 +
    <tr style="font-weight:bold">
 +
        <th width=800>Test type</th>
 +
      <th width=150><center>Current (mA)</span></center></th>
 +
      <th width=170><center>Power consumption (W)</center></th>
 +
    </tr>
 +
    <tr>
 +
        <td>Max speed LTE transmission + 1 LAN device connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> + 6 M-Bus temperature and humidity sensors connected (with Data to Server enabled) (9V)</td>
 +
      <td><center><b>551</b></center></td>
 +
      <td><center><b>4.96</b></center></td>
 +
    </tr>
 +
    <tr>
 +
        <td>Max speed LTE transmission + 1 LAN device connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> + 6 M-Bus temperature and humidity sensors connected (with Data to Server enabled) (12 V)</td>
 +
      <td><center><b>445</b></center></td>
 +
      <td><center><b>5.34</b></center></td>
 +
    </tr>
 +
    <tr>
 +
        <td>Max speed LTE transmission + 1 LAN device connected <sup><small>2</small></sup> + high CPU load <sup><small>3</small></sup> + 6 M-Bus temperature and humidity sensors connected (with Data to Server enabled) (24 V)</td>
 +
      <td><center><b>289</b></center></td>
 +
      <td><center><b>6.97</b></center></td>
 +
    </tr>
 +
</table>
 +
 +
 
<small><sup><small>1</small></sup> - Only mobile data connection established with no additional traffic.</small> <br>
 
<small><sup><small>1</small></sup> - Only mobile data connection established with no additional traffic.</small> <br>
 
<small><sup><small>2</small></sup> - Data streams between TRB143 and other connected LAN devices created using iPerf.</small> <br>
 
<small><sup><small>2</small></sup> - Data streams between TRB143 and other connected LAN devices created using iPerf.</small> <br>
 
<small><sup><small>3</small></sup> - Load created using ''md5sum'' (calculation and verification of 128-bit MD5 hashes). </small> <br>
 
<small><sup><small>3</small></sup> - Load created using ''md5sum'' (calculation and verification of 128-bit MD5 hashes). </small> <br>
 
<small>Power consumption may differ due to mobile data transmission speed, testing environment and conditions.</small>
 
<small>Power consumption may differ due to mobile data transmission speed, testing environment and conditions.</small>

Latest revision as of 14:04, 14 June 2022

Test type
Current (mA)
Power consumption (W)
Idle, no SIM card inserted (9 V)
94
0.85
Idle, no SIM card inserted (12 V)
97
1.16
Idle, no SIM card inserted (24 V)
68
1.63


Test type
Current (mA)
Power consumption (W)
Idle + mobile data on 1 (9 V)
99
0.89
Idle + mobile data on 1 (12 V)
112
1.34
Idle + mobile data on 1 (24 V)
74
1.78


Test type
Current (mA)
Power consumption (W)
Mobile data on 1 + 1 LAN device connected 2 (9 V)
152
1.37
Mobile data on 1 + 1 LAN device connected 2 (12 V)
135
1.62
Mobile data on 1 + 1 LAN device connected 2 (24 V)
103
2.47


Test type
Current (mA)
Power consumption (W)
Max speed LTE transmission + 1 LAN device connected 2 + high CPU load 3 + 6 M-Bus temperature and humidity sensors connected (with Data to Server enabled) (9V)
551
4.96
Max speed LTE transmission + 1 LAN device connected 2 + high CPU load 3 + 6 M-Bus temperature and humidity sensors connected (with Data to Server enabled) (12 V)
445
5.34
Max speed LTE transmission + 1 LAN device connected 2 + high CPU load 3 + 6 M-Bus temperature and humidity sensors connected (with Data to Server enabled) (24 V)
289
6.97


1 - Only mobile data connection established with no additional traffic.
2 - Data streams between TRB143 and other connected LAN devices created using iPerf.
3 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.