Difference between revisions of "Template:Networking trb1 manual input output status"

From Teltonika Networks Wiki
Line 1: Line 1:
 
<pre>
 
<pre>
ioman.gpio.din1
+
ioman.gpio.dio0
ioman.gpio.dout1
+
ioman.gpio.dio1
 
</pre>
 
</pre>
  
Call command <b>ubus call <i>value</i> status </b>:
+
In order to read values, call command <b>ubus call <i>value</i> status </b>:
  
  root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dout1 status
+
  root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio1 status
 
  {
 
  {
 
         "value": "0",
 
         "value": "0",
Line 28: Line 28:
 
     </li>
 
     </li>
 
</ul>
 
</ul>
 +
 +
To change input settings, use the <i><b>update</i></b> command and specify a value:
 +
 +
ubus call ioman.gpio.dio0 update '{"value":"0"}'
 +
ubus call ioman.gpio.dio0 update '{"value":"1"}'

Revision as of 08:06, 19 August 2021

ioman.gpio.dio0
ioman.gpio.dio1

In order to read values, call command ubus call value status :

root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio1 status
{
        "value": "0",
        "direction": "in",
        "bi_dir": false,
        "invert_input": false
}
  • din1 is the input:
    • "value": "0" means low level state.
    • "value": "1" means high level state.
  • dout1 is the output:
    • "value": "0" means low level state.
    • "value": "1" means high level state.

To change input settings, use the update command and specify a value:

ubus call ioman.gpio.dio0 update '{"value":"0"}'
ubus call ioman.gpio.dio0 update '{"value":"1"}'