Difference between revisions of "Template:Networking trb1 manual input output status"
From Teltonika Networks Wiki
Gytispieze (talk | contribs) |
|||
Line 1: | Line 1: | ||
<pre> | <pre> | ||
− | ioman.gpio. | + | ioman.gpio.dio0 |
− | ioman.gpio. | + | ioman.gpio.dio1 |
</pre> | </pre> | ||
− | + | In order to read values, call command <b>ubus call <i>value</i> status </b>: | |
− | root@Teltonika-{{{name}}}:~# ubus call ioman.gpio. | + | root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio1 status |
{ | { | ||
"value": "0", | "value": "0", | ||
Line 28: | Line 28: | ||
</li> | </li> | ||
</ul> | </ul> | ||
+ | |||
+ | To change input settings, use the <i><b>update</i></b> command and specify a value: | ||
+ | |||
+ | ubus call ioman.gpio.dio0 update '{"value":"0"}' | ||
+ | ubus call ioman.gpio.dio0 update '{"value":"1"}' |
Revision as of 08:06, 19 August 2021
ioman.gpio.dio0 ioman.gpio.dio1
In order to read values, call command ubus call value status :
root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio1 status { "value": "0", "direction": "in", "bi_dir": false, "invert_input": false }
- din1 is the input:
- "value": "0" means low level state.
- "value": "1" means high level state.
- dout1 is the output:
- "value": "0" means low level state.
- "value": "1" means high level state.
To change input settings, use the update command and specify a value:
ubus call ioman.gpio.dio0 update '{"value":"0"}' ubus call ioman.gpio.dio0 update '{"value":"1"}'