Difference between revisions of "Template:Networking trb1 manual input output status"
From Teltonika Networks Wiki
(Created page with " ioman.gpio.din1 ioman.gpio.dout1 Call command <b>ubus call <u>value</u> status </b>: root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dout1 status { "value": "0...") |
Gytispieze (talk | contribs) |
||
(5 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | + | <pre> | |
− | + | ioman.gpio.dio0 | |
+ | ioman.gpio.dio1 | ||
+ | </pre> | ||
− | + | In order to read values, call command <b>ubus call <i>value</i> status </b>: | |
− | root@Teltonika-{{{name}}}:~# ubus call ioman.gpio. | + | |
+ | root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio1 status | ||
{ | { | ||
"value": "0", | "value": "0", | ||
Line 12: | Line 15: | ||
<ul> | <ul> | ||
− | <li><b> | + | <li><b>dio0</b> is configurable input / output: |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
<ul> | <ul> | ||
<li>"value": "<b>0</b>" means low level state.</li> | <li>"value": "<b>0</b>" means low level state.</li> | ||
<li>"value": "<b>1</b>" means high level state.</li> | <li>"value": "<b>1</b>" means high level state.</li> | ||
+ | <li>"direction": "<b>in</b>" means input state.</li> | ||
+ | <li>"direction": "<b>out</b>" means output state.</li> | ||
</ul> | </ul> | ||
</li> | </li> | ||
</ul> | </ul> | ||
− | }} | + | |
+ | To change input settings, use the <i><b>update</i></b> command and specify a value: | ||
+ | |||
+ | ubus call ioman.gpio.dio0 update '{"value":"0"}' | ||
+ | ubus call ioman.gpio.dio0 update '{"value":"1"}' | ||
+ | ubus call ioman.gpio.dio0 update '{"direction":"in"}' | ||
+ | ubus call ioman.gpio.dio0 update '{"direction":"out"}' |
Latest revision as of 08:12, 19 August 2021
ioman.gpio.dio0 ioman.gpio.dio1
In order to read values, call command ubus call value status :
root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio1 status { "value": "0", "direction": "in", "bi_dir": false, "invert_input": false }
- dio0 is configurable input / output:
- "value": "0" means low level state.
- "value": "1" means high level state.
- "direction": "in" means input state.
- "direction": "out" means output state.
To change input settings, use the update command and specify a value:
ubus call ioman.gpio.dio0 update '{"value":"0"}' ubus call ioman.gpio.dio0 update '{"value":"1"}' ubus call ioman.gpio.dio0 update '{"direction":"in"}' ubus call ioman.gpio.dio0 update '{"direction":"out"}'