Test type Current (mA) Power consumption (W)
Idle (12 V) 77 0.93
Idle (24 V) 52 1.24
Idle (54 V) 34 1.81


Test type Current (mA) Power consumption (W)
8 LAN and 2 SFP devices connected + heavy data traffic (12 V) 381 4.57
8 LAN and 2 SFP devices connected + heavy data traffic (24 V) 200 4.80
8 LAN and 2 SFP devices connected + heavy data traffic (54 V) 103 5.54


Test type Current (mA) Power consumption (W)
2 SFP devices connected + 4 PoE devices (RUTX08, RUTX09, RUTX10, RUTX11) connected + 4 PoE dummy loads connected (30 W each) + heavy data traffic (54 V) 2405 137.10