From Teltonika Networks Wiki
Main Page > ALTOS Routers > CAP700 > CAP700 Manual > CAP700 Power ConsumptionAveraged CAP700 power consumption values in different states of operation are represented in the tables below:
| Test type |
Current (mA) |
Power consumption (W) |
| Idle, no SIM card inserted (12 V) |
308.82 |
3.7 |
| Test type |
Current (mA) |
Power consumption (W) |
| Idle + mobile data on 1 (12 V) |
313.19 |
3.76 |
| Test type |
Current (mA) |
Power consumption (W) |
| Mobile data on 1 + 1 LAN device connected 2 (12 V) |
379.96 |
4.56 |
| Test type |
Current (mA) |
Power consumption (W) |
| Max speed LTE transmission + LAN devices connected to ALL ETH ports 2 + high CPU load 3 + data transfer via WiFi (12 V) |
704.65 |
8.45 |
1 - Only mobile data connection established with no additional traffic.
2 - Data streams between CAP700 and other connected LAN devices created using iPerf.
3 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.