Difference between revisions of "Template:Networking rutos manual modbus modbus tcp get parameters table"

From Teltonika Networks Wiki
(18 intermediate revisions by 2 users not shown)
Line 26: Line 26:
 
         <td>32 bit integer</td>
 
         <td>32 bit integer</td>
 
     </tr>
 
     </tr>
 +
{{#ifeq:{{{series}}}|TRB1||
 
     <tr>
 
     <tr>
 
       <td>System temperature (in 0.1 °C)</td>
 
       <td>System temperature (in 0.1 °C)</td>
Line 33: Line 34:
 
         <td>32 bit integer</td>
 
         <td>32 bit integer</td>
 
     </tr>
 
     </tr>
 +
}}
 
}}
 
}}
 
     <tr>
 
     <tr>
Line 102: Line 104:
 
     </tr>
 
     </tr>
 
}}
 
}}
{{#ifeq:{{{name}}}|RUT955|
 
    <tr>
 
      <td>Digital input (DIN1) state</td>
 
      <td>135</td>
 
        <td>136</td>
 
      <td>2</td>
 
        <td>32 bit integer</td>
 
    </tr>
 
    <tr>
 
      <td>Digital galvanically isolated input (DIN2) state</td>
 
      <td>137</td>
 
        <td>138</td>
 
      <td>2</td>
 
        <td>32 bit integer</td>
 
    </tr>|}}
 
 
     <tr>
 
     <tr>
 
       <td>Current WAN IP address</td>
 
       <td>Current WAN IP address</td>
Line 122: Line 109:
 
         <td>140</td>
 
         <td>140</td>
 
       <td>2</td>
 
       <td>2</td>
         <td>8 bit unsigned integer</td>
+
         <td>32 bit unsigned integer</td>
 
     </tr>
 
     </tr>
 
{{#ifeq:{{{analog}}}| 1|
 
{{#ifeq:{{{analog}}}| 1|
 
     <tr>
 
     <tr>
       <td>Analog input (PIN {{#switch:{{{series}}}|TRB2=11|RUT9=9|TRB1=7}}) value</td>
+
       <td>Analog input value</td>
 
       <td>141</td>
 
       <td>141</td>
 
         <td>142</td>   
 
         <td>142</td>   
 
       <td>2</td>
 
       <td>2</td>
         <td>32 bit unsigned integer</td>
+
         <td>32 bit integer</td>
 
     </tr>
 
     </tr>
 
}}
 
}}
Line 167: Line 154:
 
         <td>180</td>
 
         <td>180</td>
 
       <td>2</td>
 
       <td>2</td>
         <td>32 bit float</td>
+
         <td>32 bit integer</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
Line 174: Line 161:
 
         <td>182</td>
 
         <td>182</td>
 
       <td>2</td>
 
       <td>2</td>
         <td>32 bit unsigned integer</td>
+
         <td>32 bit integer</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
Line 241: Line 228:
 
         <td>32 bit unsigned integer</td>
 
         <td>32 bit unsigned integer</td>
 
     </tr>
 
     </tr>
{{#ifeq:{{{name}}}|RUT955|
 
      <tr>
 
        <td>Galvanically isolated open collector output status</td>
 
        <td>201</td>
 
        <td>202</td>
 
        <td>1</td>
 
        <td>16 bit unsigned integer</td>
 
      </tr>
 
      <tr>
 
        <td>Relay output status</td>
 
        <td>202</td>
 
        <td>203</td>
 
        <td>1</td>
 
        <td>16 bit unsigned integer</td>
 
      </tr>|}}
 
 
{{#ifeq:{{{dualsim}}}| 1|
 
{{#ifeq:{{{dualsim}}}| 1|
 
       <tr>
 
       <tr>
Line 262: Line 234:
 
         <td>206</td>
 
         <td>206</td>
 
         <td>1</td>
 
         <td>1</td>
         <td>16 bit unsigned integer</td>
+
         <td>32 bit unsigned integer</td>
 
       </tr>
 
       </tr>
 
}}
 
}}
Line 293: Line 265:
 
         <td>32 bit unsigned integer</td>
 
         <td>32 bit unsigned integer</td>
 
       </tr>
 
       </tr>
{{#ifeq:{{{name}}}|RUTX12| |
+
{{#ifeq:{{{series}}}|TRB1| |
{{#switch:{{{series}}}
 
| TRB1|RUT36X|RUT2=
 
| #default =
 
 
       <tr>
 
       <tr>
 
           <td>Mobile data received today (SIM2)</td>
 
           <td>Mobile data received today (SIM2)</td>
Line 381: Line 350:
 
       <td>32 bit unsigned integer</td>
 
       <td>32 bit unsigned integer</td>
 
     </tr>
 
     </tr>
}}
 
 
}}
 
}}
 
}}
 
}}
 
{{#switch:{{{name}}}
 
{{#switch:{{{name}}}
|TCR100=
+
|RUTXR1=
|TRB245|TRB255=
+
|RUT360=
 +
|TRB255=
 
     <tr>
 
     <tr>
 
       <td>PIN 3 status</td>
 
       <td>PIN 3 status</td>
Line 401: Line 370:
 
       <td>16 bit unsigned integer</td>
 
       <td>16 bit unsigned integer</td>
 
     </tr>
 
     </tr>
|TRB140|TRB141|TRB142|TRB145|RUT300|RUT360=
 
 
     <tr>
 
     <tr>
       <td>PIN 3 status (4 PIN connector)</td>
+
      <td>PIN 2 status</td>
 +
      <td>336</td>
 +
      <td>337</td>
 +
      <td>1</td>
 +
      <td>16 bit unsigned integer</td>
 +
    </tr>
 +
|TRB245=
 +
    <tr>
 +
       <td>PIN 3 status</td>
 
       <td>324</td>
 
       <td>324</td>
 
       <td>325</td>
 
       <td>325</td>
Line 410: Line 386:
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
       <td>PIN 4 status (4 PIN connector)</td>
+
       <td>PIN 4 status</td>
 
       <td>325</td>
 
       <td>325</td>
 
       <td>326</td>
 
       <td>326</td>
 
       <td>1</td>
 
       <td>1</td>
 
       <td>16 bit unsigned integer</td>
 
       <td>16 bit unsigned integer</td>
  </tr>
+
    </tr>
 +
    <tr>
 +
      <td>PIN 2 status</td>
 +
      <td>336</td>
 +
      <td>337</td>
 +
      <td>1</td>
 +
      <td>16 bit unsigned integer</td>
 +
    </tr>
 
|
 
|
 
     <tr>
 
     <tr>
Line 422: Line 405:
 
       <td>325</td>
 
       <td>325</td>
 
       <td>1</td>
 
       <td>1</td>
       <td>16 bit unsigned integer</td>
+
       <td>32 bit unsigned integer</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
Line 429: Line 412:
 
       <td>326</td>
 
       <td>326</td>
 
       <td>1</td>
 
       <td>1</td>
       <td>16 bit unsigned integer</td>
+
       <td>32 bit unsigned integer</td>
 
</tr>
 
</tr>
 
}}
 
}}
 
{{#switch:{{{series}}}
 
{{#switch:{{{series}}}
|TCR1=
+
|RUTX=
|RUTX|TRB2|RUT9|RUT2|RUT2M=
+
|TRB2XX=
 +
|RUT36X=
 
|
 
|
 
     <tr>
 
     <tr>
Line 451: Line 435:
 
   </tr>
 
   </tr>
 
}}
 
}}
 +
{{#ifeq:{{{mobile}}}|1|
 
     <tr>
 
     <tr>
 
       <td> Modem ID </td>
 
       <td> Modem ID </td>
Line 458: Line 443:
 
       <td>Text</td>
 
       <td>Text</td>
 
   </tr>
 
   </tr>
{{#ifeq:{{{series}}}|TRB2|
 
    <tr>
 
      <td>PIN 2 status</td>
 
      <td>336</td>
 
      <td>337</td>
 
      <td>1</td>
 
      <td>16 bit unsigned integer</td>
 
    </tr>
 
 
}}
 
}}
 
{{#ifeq:{{{name}}}|TRB141|
 
{{#ifeq:{{{name}}}|TRB141|
Line 521: Line 498:
 
       <td>344</td>
 
       <td>344</td>
 
       <td>345</td>
 
       <td>345</td>
      <td>1</td>
 
      <td>16 bit unsigned integer</td>
 
  </tr>
 
    <tr>
 
      <td> ACL activity </td>
 
      <td>345</td>
 
      <td>346</td>
 
 
       <td>1</td>
 
       <td>1</td>
 
       <td>16 bit unsigned integer</td>
 
       <td>16 bit unsigned integer</td>
Line 535: Line 505:
 
       <td>346</td>
 
       <td>346</td>
 
       <td>347</td>
 
       <td>347</td>
       <td>2</td>
+
       <td>1</td>
       <td>32 bit float</td>
+
       <td>32 bit integer</td>
 
   </tr>
 
   </tr>
 
}}
 
}}
Line 548: Line 518:
 
   </tr>
 
   </tr>
 
}}
 
}}
    <tr>
 
      <td> Unix timestamp </td>
 
      <td>364</td>
 
      <td>365</td>
 
      <td>2</td>
 
      <td>32 bit unsigned integer</td>
 
  </tr>
 
    <tr>
 
      <td> Local ISO time </td>
 
      <td>366</td>
 
      <td>367</td>
 
      <td>12</td>
 
      <td>Text</td>
 
  </tr>
 
    <tr>
 
      <td> UTC time </td>
 
      <td>378</td>
 
      <td>389</td>
 
      <td>12</td>
 
      <td>Text</td>
 
  </tr>
 
 
</table>
 
</table>

Revision as of 10:39, 21 July 2021

Get Parameters


Modbus parameters are held within registers. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). The register numbers and corresponding system values are described in the table below:

required value register address register number number of registers representation
System uptime 1 2 2 32 bit unsigned integer
System hostname 7 8 16 Text
Router serial number 39 40 16 Text
LAN MAC address 55 56 16 Text
Router name 71 72 16 Text
Current WAN IP address 139 140 2 32 bit unsigned integer
Digital non-isolated input (4 PIN connector) 324 325 1 32 bit unsigned integer
Digital open collector output (4 PIN connector) 325 326 1 32 bit unsigned integer
PIN 3 direction 326 327 1 16 bit unsigned integer
PIN 4 direction 327 328 1 16 bit unsigned integer