RUT955 Current Measurement with Analog Input

From Teltonika Networks Wiki
Revision as of 13:12, 12 June 2020 by Dziugas (talk | contribs) (Created page with "If you want to measure the current with RUT955 you need to connect a resistor as shown in the picture below. Note that voltage on pin 9 must never exceed 24V. File:Rut955 a...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > RUT Routers > RUT955 > RUT955 Hardware Application Examples > RUT955 Current Measurement with Analog Input

If you want to measure the current with RUT955 you need to connect a resistor as shown in the picture below. Note that voltage on pin 9 must never exceed 24V.

Rut955 analog input current measurement.png

Configure resistor value and analog input name in the router's WebUI (see here).

This is commonly used with 4-20mA standard sensors. If your sensor has linear characteristics, you can also configure a sensor slope and offset to directly get measured values.