Difference between revisions of "RUT955 Input/Output"

From Teltonika Networks Wiki
Line 19: Line 19:
 
| file_output_scheduler = Networking_rut955_manual_input_output_output_scheduler_v1.png
 
| file_output_scheduler = Networking_rut955_manual_input_output_output_scheduler_v1.png
 
}}
 
}}
 
===Periodic Control===
 
----
 
The '''Periodic control''' section allows you to set up automatic output control rules that trigger output state changes at the specified period or interval.
 
 
[[File:Services inputoutput output periodic v2.png]]
 
 
<table class="nd-mantable">
 
    <tr>
 
        <th>field name</th>
 
      <th>value</th>
 
      <th>description</th>
 
    </tr>
 
    <tr>
 
      <td>Enable</td>
 
      <td>yes | no; Default: '''no'''</td>
 
      <td>Toggles the rule ON or OFF</td>
 
    </tr>
 
    <tr>
 
      <td>Output</td>
 
      <td>Digital OC output | Digital Relay output; Default: '''Digital OC output'''</td>
 
      <td>To which output the rule pertains </td>
 
    </tr>
 
    <tr>
 
    <td>Action</td>
 
        <td>On | Off; Default: '''On'''</td>
 
        <td>Periodic action to be taken</td>
 
    </tr>
 
    <tr>
 
    <td>Action timeout</td>
 
        <td>yes | no; Default: '''no'''</td>
 
        <td>Activates action timeout. Action timeout specifies whether an action should end after some time. For example, if the specified Action is to turn Digital OC output On and the action triggers, the Action timeout then turns Digital OC output back off after a specified amount of time in seconds specified in this field </td>
 
    </tr>
 
    <tr>
 
    <td>Timeout (sec)</td>
 
        <td>integer; Default: " "</td>
 
        <td>Specifies how long the Action timeout is</td>
 
    </tr>
 
    <tr>
 
    <td>Mode</td>
 
        <td>Fixed | Interval; Default: '''Fixed'''</td>
 
        <td>'''Fixed''' mode triggers the specified action on a specified day(s), hour and minute. For example, every Sunday at 8:30 AM<br>
 
 
'''Interval''' provides you with the possibility to set up an interval after which the same action takes place</td>
 
    </tr>
 
</table>
 
 
===Scheduler===
 
----
 
The '''Scheduler''' lets you configure a schedule of when certain outputs are to be enabled or disabled.
 
 
[[File:Services inputoutput output scheduler v2.png]]
 
  
 
==Additional Information==
 
==Additional Information==
  
* Input/Output hardware application examples:
+
<b>Input/Output hardware application examples</b>
** '''[[RUT955 Connecting relay to open collector output|Connecting relay to open collector output]]'''
 
** '''[[Inverting RUT955 relay output polarity|Inverting relay output polarity]]'''
 
** '''[[Using RUT955 Inputs for security applications|Using Inputs for security applications]]'''
 
** '''[[Current measurement with RUT955 analog input|Current measurement with analog input]]'''
 
  
[[Category:RUT955 WebUI]]
+
<ul>
 +
    <li></b>[[RUT955 Connecting relay to open collector output|Connecting relay to open collector output]]</b></li>
 +
    <li></b>[[Inverting RUT955 relay output polarity|Inverting relay output polarity]]</b></li>
 +
    <li></b>[[Using RUT955 Inputs for security applications|Using Inputs for security applications]]</b></li>
 +
    <li></b>[[Current measurement with RUT955 analog input|Current measurement with analog input]]</b></li>
 +
</ul>

Revision as of 16:09, 29 July 2019

Main Page > RUT Routers > RUT955 > RUT955 Manual > RUT955 WebUI > RUT955 Services section > RUT955 Input/Output