RUTXR1 Power Consumption

From Teltonika Networks Wiki
Revision as of 14:10, 10 June 2020 by Dziugas (talk | contribs) (Created page with "{{Template: Networking_rutx_manual_power_consumption | name = RUTXR1 }}")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > RUTX Routers > RUTXR1 > RUTXR1 Manual > RUTXR1 Power Consumption

RUTXR1 power consumption values in different states of operation are represented in the tables below:

Test type Current (mA) Power consumption (W)
Idle, no SIM card inserted (9 V) 441 3.97
Idle, no SIM card inserted (12 V) 330 3.96
Idle, no SIM card inserted (24 V) 174 4.18


Test type Current (mA) Power consumption (W)
Idle + mobile data on 1 (9 V) 447 4.02
Idle + mobile data on 1 (12 V) 334 4.01
Idle + mobile data on 1 (24 V) 175 4.20


Test type Current (mA) Power consumption (W)
Mobile data on 1 + 1 LAN device connected 2 (9 V) 515 4.64
Mobile data on 1 + 1 LAN device connected 2 (12 V) 390 4.68
Mobile data on 1 + 1 LAN device connected 2 (24 V) 196 4.70


Test type Current (mA) Power consumption (W)
Max speed LTE transmission + 5 LAN devices connected 2 + high CPU load 3 + data transfer via WiFi + USB device connected 4 (9 V) 1235 11.12
Max speed LTE transmission + 5 LAN devices connected 2 + high CPU load 3 + data transfer via WiFi + USB device connected 4 (12 V) 9.24 11.09
Max speed LTE transmission + 5 LAN devices connected 2 + high CPU load 3 + data transfer via WiFi + USB device connected 4 (24 V) 464 11.14

1 - Only mobile data connection established with no additional traffic.
2 - Data streams between RUTXR1 and other connected LAN devices created using iPerf.
3 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
4 - USB device with ~ 300 mA current draw.
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.