Changes

Line 56: Line 56:  
! 3  
 
! 3  
 
| Spraying water || Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with a counterbalanced shield.   
 
| Spraying water || Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with a counterbalanced shield.   
Test a) is conducted for 5 minutes, then repeated with the specimen rotated horizontally by 90° for the second 5-minute test. Test b) is conducted (with shield in place) for 5 minutes minimum. || For a Spray Nozzle:
+
Test a) is conducted for 5 minutes, then repeated with the specimen rotated horizontally by 90° for the second 5-minute test. Test b) is conducted (with shield in place) for 5 minutes minimum. || For a Spray Nozzle:<br />
 
Test duration: 1 minute per square meter for at least 5&nbsp;minutes<br />
 
Test duration: 1 minute per square meter for at least 5&nbsp;minutes<br />
 
Water volume: 10&nbsp;litres per minute<br />
 
Water volume: 10&nbsp;litres per minute<br />
Pressure: 50–150&nbsp;kPa
+
Pressure: 50–150&nbsp;kPa<br />
For an oscillating tube:
+
For an oscillating tube:<br />
Test duration: 10 minutes
+
Test duration: 10 minutes<br />
Water Volume: 0.07 l/min per hole
+
Water Volume: 0.07 l/min per hole<br />
 
|}
 
|}
0