Template:Networking rut300 manual power consumption table

From Teltonika Networks Wiki
Test type
Current (mA)
Power consumption (W)
Idle (9 V)
68
0.61
Idle (12 V)
53
0.64
Idle (24 V)
29
0.70


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected 1 (9 V)
114
1.03
2 LAN devices connected 1 (12 V)
86
1.03
2 LAN devices connected 1 (24 V)
45
1.08


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (9 V)
497
4.47
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (12 V)
373
4.48
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (24 V)
192
4.61


1 - Only mobile data connection established with no additional traffic.
2 - Data streams between RUT300 and other connected LAN devices created using iPerf.
3 - USB device with ~ 300 mA current draw.
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.