Template:Networking rut300 manual power consumption table

From Teltonika Networks Wiki
Revision as of 15:59, 23 February 2022 by Paulius R (talk | contribs)

Test type Current (mA) Power consumption (W)
Idle (9 V) 68 0.61
Idle (12 V) 53 0.64
Idle (24 V) 29 0.70


Test type Current (mA) Power consumption (W)
2 LAN devices connected 1 (9 V) 114 1.03
2 LAN devices connected 1 (12 V) 86 1.03
2 LAN devices connected 1 (24 V) 45 1.08


Test type Current (mA) Power consumption (W)
2 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (9 V) 497 4.47
2 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (12 V) 373 4.48
2 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (24 V) 192 4.61

1 - Only mobile data connection established with no additional traffic.
2 - Data streams between RUT300 and other connected LAN devices created using iPerf.
3 - USB device with ~ 300 mA current draw.
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.