Template:Networking rut955 manual modbus modbus tcp get parameters table

From Teltonika Networks Wiki
Revision as of 12:17, 4 December 2018 by Dziugas (talk | contribs) (Created page with "<table class="nd-othertables"> <tr> <th style="width: 566px">required value</th> <th style="width: 200px">register number</th> <th style="width: 20...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
required value register number number of registers representaion
System uptime 1 2 32 bit unsigned integer
Mobile signal strength (RSSI in dBm) 3 2 32 bit integer
System temperature (in 0.1 °C) 5 2 32 bit integer
System hostname 7 16 Text
GSM operator name 23 16 Text
Router serial number 39 16 Text
LAN MAC address 55 16 Text
Router name 71 16 Text
Currently active SIM card slot 87 16 Text
Network registration info 103 16 Text
Network type 119 16 Text
Digital input (DIN1) state 135 2 32 bit integer
Digital galvanically isolated input (DIN2) state 137 2 32 bit integer
Current WAN IP address 139 16 32 bit unsigned integer
Analog input value 141 16 32 bit integer
GPS latitude coordinate 143 2 32 bit float
GPS longitude coordinate 145 2 32 bit float
GPS fix time 147 16 Text (Unix timestamp×1000)
GPS date and time 163 16 Text (DDMMYYhhmmss)
GPS speed 179 2 32 bit integer
GPS satellite count 181 2 32 bit integer
GPS accuracy 183 2 32 bit float