Changes

no edit summary
Line 1: Line 1: −
<pre>
+
{{#ifeq:{{{name}}}|RUT955|
ioman.gpio.din1    - 4PIN input
+
<pre>
ioman.gpio.dout1  - 4PIN output
+
ioman.gpio.din1    - 4PIN input
ioman.gpio.din2    - Digital input (only for passive sensors)
+
ioman.gpio.dout1  - 4PIN output
ioman.gpio.dout2  - Galvanically isolated open collector output
+
ioman.gpio.din2    - Digital input (only for passive sensors)
ioman.relay.relay0 - Digital relay output
+
ioman.gpio.dout2  - Galvanically isolated open collector output
ioman.gpio.iio    - Digital galvanically isolated input  
+
ioman.relay.relay0 - Digital relay output
ioman.adc.adc0    - Analog input
+
ioman.gpio.iio    - Digital galvanically isolated input  
ioman.acl.acl0    - Analog Current loop
+
ioman.adc.adc0    - Analog input
 +
ioman.acl.acl0    - Analog Current loop
 +
</pre>|
 +
<pre>
 +
ioman.gpio.din1    - 4PIN input
 +
ioman.gpio.dout1  - 4PIN output
 +
</pre>
 +
}}
    
Call command <b>ubus call <u>value</u> status </b>:
 
Call command <b>ubus call <u>value</u> status </b>:
Line 30: Line 37:  
             <li>"value": "<b>1</b>" means high level state.</li>
 
             <li>"value": "<b>1</b>" means high level state.</li>
 
         </ul>
 
         </ul>
     </li>
+
     </li>{{#ifeq:{{{name}}}|RUT955|
 +
    <li><b>relay0</b> is the relay:
 +
        <ul>
 +
            <li>"state": "<b>open</b>" means open relay state.</li>
 +
            <li>"state": "<b>closed</b>" means closed relay state.</li>
 +
        </ul>
 +
    </li>|}}
 
</ul>
 
</ul>
 +
 +
{{#ifeq:{{{name}}}|RUT955|
 +
To change relay settings, use the <i><b>update</i></b> command and specify a state:
 +
 +
ubus call ioman.relay.relay0 update '{"state":"open"}'
 +
ubus call ioman.relay.relay0 update '{"state":"closed"}'
 +
|}}