Template:Networking rut9 manual input output status

From Teltonika Networks Wiki
 ioman.gpio.din1    - 4PIN input
 ioman.gpio.dout1   - 4PIN output
 ioman.gpio.din2    - Digital input (only for passive sensors)
 ioman.gpio.dout2   - Galvanically isolated open collector output
 ioman.relay.relay0 - Digital relay output
 ioman.gpio.iio     - Digital galvanically isolated input 
 ioman.adc.adc0     - Analog input
 ioman.acl.acl0     - Analog Current loop

Call command ubus call value status :
 root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.din1 status
 {
         "value": "0",
         "direction": "in",
         "bi_dir": false,
         "invert_input": false
 }

  • din1 is the input:
    • "value": "0" means low level state.
    • "value": "1" means high level state.
  • dout1 is the output:
    • "value": "0" means low level state.
    • "value": "1" means high level state.