Difference between revisions of "Template:Networking rutos manual modbus modbus tcp get parameters table"

From Teltonika Networks Wiki
(Created page with "<table class="nd-othertables"> <tr> <th width="546">required value</th> <th width="200">register address</th> <th width="200">register number</th>...")
 
(20 intermediate revisions by 4 users not shown)
Line 1: Line 1:
 +
===Get Parameters===
 +
----
 +
Modbus parameters are held within <b>registers</b>. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). The register numbers and corresponding system values are described in the table below:
 +
<br> <br>
 
<table class="nd-othertables">
 
<table class="nd-othertables">
 
     <tr>
 
     <tr>
Line 22: Line 26:
 
         <td>32 bit integer</td>
 
         <td>32 bit integer</td>
 
     </tr>
 
     </tr>
{{#ifeq:{{{series}}}|TRB14X||
 
 
     <tr>
 
     <tr>
 
       <td>System temperature (in 0.1 °C)</td>
 
       <td>System temperature (in 0.1 °C)</td>
Line 30: Line 33:
 
         <td>32 bit integer</td>
 
         <td>32 bit integer</td>
 
     </tr>
 
     </tr>
}}
 
 
}}
 
}}
 
     <tr>
 
     <tr>
Line 76: Line 78:
 
     </tr>
 
     </tr>
 
{{#ifeq:{{{mobile}}}| 1 |
 
{{#ifeq:{{{mobile}}}| 1 |
 +
{{#ifeq:{{{dualsim}}}| 1|
 
     <tr>
 
     <tr>
 
       <td>Currently active SIM card slot</td>
 
       <td>Currently active SIM card slot</td>
Line 83: Line 86:
 
         <td>Text</td>
 
         <td>Text</td>
 
     </tr>
 
     </tr>
 +
}}
 
     <tr>
 
     <tr>
 
       <td>Network registration info</td>
 
       <td>Network registration info</td>
Line 98: Line 102:
 
     </tr>
 
     </tr>
 
}}
 
}}
 +
{{#ifeq:{{{name}}}|RUT955|
 +
    <tr>
 +
      <td>Digital input (DIN1) state</td>
 +
      <td>135</td>
 +
        <td>136</td>
 +
      <td>2</td>
 +
        <td>32 bit integer</td>
 +
    </tr>
 +
    <tr>
 +
      <td>Digital galvanically isolated input (DIN2) state</td>
 +
      <td>137</td>
 +
        <td>138</td>
 +
      <td>2</td>
 +
        <td>32 bit integer</td>
 +
    </tr>|}}
 
     <tr>
 
     <tr>
 
       <td>Current WAN IP address</td>
 
       <td>Current WAN IP address</td>
Line 222: Line 241:
 
         <td>32 bit unsigned integer</td>
 
         <td>32 bit unsigned integer</td>
 
     </tr>
 
     </tr>
}}
+
{{#ifeq:{{{name}}}|RUT955|
{{#ifeq:{{{mobile}}}| 1|
+
      <tr>
 +
        <td>Galvanically isolated open collector output status</td>
 +
        <td>201</td>
 +
        <td>202</td>
 +
        <td>1</td>
 +
        <td>16 bit unsigned integer</td>
 +
      </tr>
 +
      <tr>
 +
        <td>Relay output status</td>
 +
        <td>202</td>
 +
        <td>203</td>
 +
        <td>1</td>
 +
        <td>16 bit unsigned integer</td>
 +
      </tr>|}}
 +
{{#ifeq:{{{dualsim}}}| 1|
 
       <tr>
 
       <tr>
 
         <td>Active SIM card</td>
 
         <td>Active SIM card</td>
Line 231: Line 264:
 
         <td>32 bit unsigned integer</td>
 
         <td>32 bit unsigned integer</td>
 
       </tr>
 
       </tr>
 +
}}
 
       <tr>
 
       <tr>
 
         <td>Mobile data received last week (SIM1)</td>
 
         <td>Mobile data received last week (SIM1)</td>
Line 259: Line 293:
 
         <td>32 bit unsigned integer</td>
 
         <td>32 bit unsigned integer</td>
 
       </tr>
 
       </tr>
{{#ifeq:{{{series}}}|TRB14X| |
+
{{#ifeq:{{{name}}}|RUTX12| |
 +
{{#switch:{{{series}}}
 +
| TRB1|RUT36X|RUT2=
 +
| #default =
 
       <tr>
 
       <tr>
 
           <td>Mobile data received today (SIM2)</td>
 
           <td>Mobile data received today (SIM2)</td>
Line 344: Line 381:
 
       <td>32 bit unsigned integer</td>
 
       <td>32 bit unsigned integer</td>
 
     </tr>
 
     </tr>
 +
}}
 
}}
 
}}
 
}}
 
}}
Line 392: Line 430:
 
       <td>16 bit unsigned integer</td>
 
       <td>16 bit unsigned integer</td>
 
     </tr>
 
     </tr>
 +
|TRB140|TRB141|TRB142|TRB145|RUT300|RUT360=
 +
    <tr>
 +
      <td>PIN 3 status (4 PIN connector)</td>
 +
      <td>324</td>
 +
      <td>325</td>
 +
      <td>1</td>
 +
      <td>16 bit unsigned integer</td>
 +
    </tr>
 +
    <tr>
 +
      <td>PIN 4 status (4 PIN connector)</td>
 +
      <td>325</td>
 +
      <td>326</td>
 +
      <td>1</td>
 +
      <td>16 bit unsigned integer</td>
 +
  </tr>
 
|
 
|
 
     <tr>
 
     <tr>
Line 410: Line 463:
 
{{#switch:{{{series}}}
 
{{#switch:{{{series}}}
 
|RUTX=
 
|RUTX=
 +
|TRB2XX=
 +
|RUT9=
 
|
 
|
 
     <tr>
 
     <tr>
       <td> PIN 3 direction {{#ifeq:{{{series}}}|TRB14X|(4 PIN connector)}}</td>
+
       <td> PIN 3 direction {{#ifeq:{{{series}}}|TRB1|(4 PIN connector)}}</td>
 
       <td>326</td>
 
       <td>326</td>
 
       <td>327</td>
 
       <td>327</td>
Line 419: Line 474:
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
       <td> PIN 4 direction {{#ifeq:{{{series}}}|TRB14X|(4 PIN connector)}} </td>
+
       <td> PIN 4 direction {{#ifeq:{{{series}}}|TRB1|(4 PIN connector)}} </td>
 
       <td>327</td>
 
       <td>327</td>
 
       <td>328</td>
 
       <td>328</td>

Revision as of 09:49, 26 October 2021

Get Parameters


Modbus parameters are held within registers. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). The register numbers and corresponding system values are described in the table below:

required value register address register number number of registers representation
System uptime 1 2 2 32 bit unsigned integer
System hostname 7 8 16 Text
Router serial number 39 40 16 Text
LAN MAC address 55 56 16 Text
Router name 71 72 16 Text
Current WAN IP address 139 140 2 32 bit unsigned integer
Digital non-isolated input (4 PIN connector) 324 325 1 32 bit unsigned integer
Digital open collector output (4 PIN connector) 325 326 1 32 bit unsigned integer
PIN 3 direction 326 327 1 16 bit unsigned integer
PIN 4 direction 327 328 1 16 bit unsigned integer