Difference between revisions of "Template:Networking rutos manual modbus modbus tcp get parameters table"
From Teltonika Networks Wiki
(Created page with "<table class="nd-othertables"> <tr> <th width="546">required value</th> <th width="200">register address</th> <th width="200">register number</th>...") |
|||
Line 1: | Line 1: | ||
+ | ===Get Parameters=== | ||
+ | ---- | ||
+ | Modbus parameters are held within <b>registers</b>. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). The register numbers and corresponding system values are described in the table below: | ||
+ | <br> <br> | ||
<table class="nd-othertables"> | <table class="nd-othertables"> | ||
<tr> | <tr> |
Revision as of 14:27, 15 July 2020
Get Parameters
Modbus parameters are held within registers. Each register contains 2 bytes of information. For simplification, the number of registers for storing numbers is 2 (4 bytes), while the number of registers for storing text information is 16 (32 bytes). The register numbers and corresponding system values are described in the table below:
required value | register address | register number | number of registers | representation |
---|---|---|---|---|
System uptime | 1 | 2 | 2 | 32 bit unsigned integer |
System hostname | 7 | 8 | 16 | Text |
Router serial number | 39 | 40 | 16 | Text |
LAN MAC address | 55 | 56 | 16 | Text |
Router name | 71 | 72 | 16 | Text |
Current WAN IP address | 139 | 140 | 2 | 32 bit unsigned integer |
Digital non-isolated input (4 PIN connector) | 324 | 325 | 1 | 32 bit unsigned integer |
Digital open collector output (4 PIN connector) | 325 | 326 | 1 | 32 bit unsigned integer |
PIN 3 direction | 326 | 327 | 1 | 16 bit unsigned integer |
PIN 4 direction | 327 | 328 | 1 | 16 bit unsigned integer |