Difference between revisions of "Template:Networking rutos manual modbus modbus tcp set parameters table"

From Teltonika Networks Wiki
(Created page with "<table class="nd-othertables"> <tr> <th width="350">value to set</th> <th width="180">register address</th> <th width="150">register value</th>...")
 
Line 1: Line 1:
 +
===Set Parameters===
 +
----
 +
The Modbus daemon can also set some device parameters. These parameters and explanations on how to use them are described in the table below:
 +
<br> <br>
 
<table class="nd-othertables">
 
<table class="nd-othertables">
 
     <tr>
 
     <tr>

Revision as of 14:29, 15 July 2020

Set Parameters


The Modbus daemon can also set some device parameters. These parameters and explanations on how to use them are described in the table below:

value to set register address register value description
Reboot 206 1 Reboots the router
Switch PIN 3 state 324 1|0 Toggles PIN 3 ON or OFF, when output is selected
Switch PIN 4 state 325 1|0 Toggles PIN 4 ON or OFF, when output is selected