Difference between revisions of "Template:Networking trb2 manual input output status"
From Teltonika Networks Wiki
Line 1: | Line 1: | ||
<pre> | <pre> | ||
− | ioman.adc.adc0 | + | ioman.adc.adc0 - Analog input |
− | ioman.gpio.dio0 | + | ioman.gpio.dio0 - Configurable input/output (PIN2) |
− | ioman.gpio.dio1 | + | ioman.gpio.dio1 - Configurable input/output (PIN3) |
− | ioman.gpio.dio2 | + | ioman.gpio.dio2 - Configurable input/output (PIN4) |
</pre> | </pre> | ||
Revision as of 14:55, 21 June 2021
ioman.adc.adc0 - Analog input ioman.gpio.dio0 - Configurable input/output (PIN2) ioman.gpio.dio1 - Configurable input/output (PIN3) ioman.gpio.dio2 - Configurable input/output (PIN4)
Call command ubus call value status :
root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status { "value": "0", "direction": "out", "bi_dir": true, "invert_input": false }
- dio0 is configurable input / output:
- "value": "0" means low level state.
- "value": "1" means high level state.
- adc0 is analog input:
- "value": "0.54" means 0.54V.