Difference between revisions of "Template:Networking trb2 manual input output status"

From Teltonika Networks Wiki
(Created page with " ioman.adc.adc0 ioman.gpio.dio0 ioman.gpio.dio1 ioman.gpio.dio2 Call command <b>ubus call <u>value</u> status </b>: root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0...")
 
Line 1: Line 1:
ioman.adc.adc0
+
<pre>
ioman.gpio.dio0
+
ioman.adc.adc0
ioman.gpio.dio1
+
ioman.gpio.dio0
ioman.gpio.dio2
+
ioman.gpio.dio1
 +
ioman.gpio.dio2
 +
</pre>
 +
 
 +
Call command <b>ubus call <i>value</i> status </b>:
  
Call command <b>ubus call <u>value</u> status </b>:
 
 
  root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status
 
  root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status
 
  {
 
  {

Revision as of 10:07, 4 November 2020

ioman.adc.adc0
ioman.gpio.dio0
ioman.gpio.dio1
ioman.gpio.dio2

Call command ubus call value status :

root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status
{
        "value": "0",
        "direction": "out",
        "bi_dir": true,
        "invert_input": false
}
  • dio0 is configurable input / output:
    • "value": "0" means low level state.
    • "value": "1" means high level state.
  • adc0 is analog input:
    • "value": "0.54" means 0.54V.