Test type Current (mA) Power consumption (W)
Idle (7 V) 91 0.65
Idle (12 V) 57 0.68
Idle (24 V) 32 0.76
Idle (54 V) 18 0.95
Idle (57 V) 18 1.03


Test type Current (mA) Power consumption (W)
2 LAN devices connected + heavy data traffic1 (7 V) 140 0.98
2 LAN devices connected + heavy data traffic1 (12 V) 86 1.03
2 LAN devices connected + heavy data traffic1 (24 V) 46 1.10
2 LAN devices connected + heavy data traffic1 (54 V) 25 1.35
2 LAN devices connected + heavy data traffic1 (57 V) 24 1.37


Test type Current (mA) Power consumption (W)
2 SFP and 8 LAN devices connected + heavy data traffic1 (7 V) 455 3.19
2 SFP and 8 LAN devices connected + heavy data traffic1 (12 V) 269 3.23
2 SFP and 8 LAN devices connected + heavy data traffic1 (24 V) 139 3.37
2 SFP and 8 LAN devices connected + heavy data traffic1 (54 V) 68 3.67
2 SFP and 8 LAN devices connected + heavy data traffic1 (57 V) 65 3.71

1 - Data streams between devices were created using iPerf3.
Power consumption may differ due to testing environment and conditions.