Difference between revisions of "TSW212 Power Consumption"

From Teltonika Networks Wiki
 
(No difference)

Latest revision as of 09:22, 25 October 2023

Main Page > TSW Switches > TSW212 > TSW212 Manual > TSW212 Power Consumption
Test type
Current (mA)
Power consumption (W)
Idle (9 V)
141
1.27
Idle (12 V)
109
1.31
Idle (24 V)
57
1.37
Idle (44 V)
33
1.45
Idle (50 V)
29
1.45
Idle (57 V)
26
1.48


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
236
2.12
2 LAN devices connected + heavy data traffic1 (12 V)
179
2.15
2 LAN devices connected + heavy data traffic1 (24 V)
95
2.28
2 LAN devices connected + heavy data traffic1 (44 V)
54
2.38
2 LAN devices connected + heavy data traffic1 (50 V)
48
2.40
2 LAN devices connected + heavy data traffic1 (57 V)
43
2.45


Test type
Current (mA)
Power consumption (W)
2 SFP and 8 LAN devices connected + heavy data traffic1 (9 V)
506
4.55
2 SFP and 8 LAN devices connected + heavy data traffic1 (12 V)
379
4.55
2 SFP and 8 LAN devices connected + heavy data traffic1 (24 V)
195
4.68
2 SFP and 8 LAN devices connected + heavy data traffic1 (44 V)
111
4.88
2 SFP and 8 LAN devices connected + heavy data traffic1 (50 V)
99
4.95
2 SFP and 8 LAN devices connected + heavy data traffic1 (57 V)
88
5.02


1 - Data streams between devices were created using iPerf3.