Inputs and outputs are used for monitoring and controlling a connected device or receiving signals from that device in order to trigger certain events.
 
Inputs and outputs are used for monitoring and controlling a connected device or receiving signals from that device in order to trigger certain events.
   −
1-Wire is a voltage-based digital system that works with two contacts, data and ground, for half-duplex bidirectional communication. Compared to other serial communication systems such as I2C or SPI, 1-Wire devices are designed for use in a momentary contact environment.
+
1-Wire is a voltage-based digital system that works with two contacts, data and ground, for half-duplex bidirectional communication. Compared to other serial communication systems such as I2C or SPI, 1-Wire devices are designed for use in a momentary contact environment. It is developed by Dallas Semiconductor (now Maxim Integrated) that allows devices to communicate over a single wire using a complex protocol to transfer data. The 1-Wire protocol is commonly used for low-speed communication between microcontrollers and their peripherals, such as temperature sensors, memory devices, and other digital and analog sensors.
 +
 
 +
Currently, only one Teltonika device (TRB141) supports 1-Wire communication protocol.
    
In this chapter, we will set up and configure the 1-Wire sensor with '''TRB141'''.
 
In this chapter, we will set up and configure the 1-Wire sensor with '''TRB141'''.
Line 17: Line 19:  
==Connecting 1-Wire Sensor with TRB141==
 
==Connecting 1-Wire Sensor with TRB141==
   −
First of all we will connect the 1-Wire sensor with TRB141, for this example, I will be using two different 1-Wire sensors Dallas DS1820 and Dallas DS9092.
+
First of all we will connect the 1-Wire sensor with TRB141, for this example, we will be using two different 1-Wire sensors Dallas DS1820 and Dallas DS9092.
 
Before we proceed with the connection, make sure you know how your 1-Wire sensor has to be connected, or open your 1-Wire sensor data sheet to reference where each wire should be connected.
 
Before we proceed with the connection, make sure you know how your 1-Wire sensor has to be connected, or open your 1-Wire sensor data sheet to reference where each wire should be connected.
    
===DS1820 connection===
 
===DS1820 connection===
 
+
----
 
The wiring for DS1820 can be seen in the picture provided below. We will connect the 1st wire to TRB141, the second wire to the 1-Wire pin on TRB141, and the 3rd wire to the + pin. Please see the Wiring of DS1820 and Pinout of TRB141 on which pins should be connected.
 
The wiring for DS1820 can be seen in the picture provided below. We will connect the 1st wire to TRB141, the second wire to the 1-Wire pin on TRB141, and the 3rd wire to the + pin. Please see the Wiring of DS1820 and Pinout of TRB141 on which pins should be connected.
    
====Wiring====
 
====Wiring====
 
+
----
 
[[File:Networking rut configuration 1 wire wiring v1.png|border|class=tlt-border]]
 
[[File:Networking rut configuration 1 wire wiring v1.png|border|class=tlt-border]]
    
====Pinout====
 
====Pinout====
 
+
----
[[File:Networking trb141 manual input output input output connector pinout v3.png|border|class=tlt-border]]
+
[[File:Networking trb141 manual input output input output connector pinout v7.png|border|class=tlt-border]]
    
* 1 - Red Wire
 
* 1 - Red Wire
 
* 2 - White Wire
 
* 2 - White Wire
 
* 3 - Green Wire
 
* 3 - Green Wire
  −
====Picture-example====
  −
  −
And here you can see real-life connection example of TRB141 with DS1820:
  −
  −
[[File:Networking rut configuration 1 wire wiring example v2.png|border|class=tlt-border]]
      
----
 
----
    
===DS9092 connection===
 
===DS9092 connection===
 
+
----
 
'''Note: Keep in mind that the wire colors of your Ibutton can be different to ones used for this example.'''
 
'''Note: Keep in mind that the wire colors of your Ibutton can be different to ones used for this example.'''
   Line 51: Line 47:     
====Wiring====
 
====Wiring====
 
+
----
 
[[File:Networking rut configuration 1 wire wiring DS9092 v1.png|border|class=tlt-border]]
 
[[File:Networking rut configuration 1 wire wiring DS9092 v1.png|border|class=tlt-border]]
    
====Pinout====
 
====Pinout====
 
+
----
 
[[File:Networking trb141 manual input output input output connector pinout v4.png|border|class=tlt-border]]
 
[[File:Networking trb141 manual input output input output connector pinout v4.png|border|class=tlt-border]]
   Line 62: Line 58:     
====Picture-example====
 
====Picture-example====
 +
----
 +
    
[[File:Networking rut configuration 1 wire wiring example v3.jpg|border|class=tlt-border]]
 
[[File:Networking rut configuration 1 wire wiring example v3.jpg|border|class=tlt-border]]
Line 75: Line 73:     
===1-Wire activation commands===
 
===1-Wire activation commands===
 
+
----
 
In order to read one-wire sensor data you will need to follow these steps:
 
In order to read one-wire sensor data you will need to follow these steps:
   Line 96: Line 94:  
[[File:Networking trb141 configuration 1 wire cli commands test v1.png|border|class=tlt-border|1100px]]
 
[[File:Networking trb141 configuration 1 wire cli commands test v1.png|border|class=tlt-border|1100px]]
    +
 +
==Connecting Multiple 1-Wire Sensors with TRB141==
 +
 +
The configuration for connecting multiple 1-wire sensors is the same as above.
 +
There’s no restriction or limit on the number of sensors that can be connected to TRB141. However, there’s a limit on how many sensors can be read every second which is up to 75 sensors only.
 +
 +
===DS18B20 connection===
 +
----
 +
The wiring image is a similar scheme that we used as our guide for connecting multiple 1-Wire sensors on the TRB141.
 +
 +
====Wiring====
 +
----
 +
[[File:Networking trb1 configuration connectionguide v1.png|border|class=tlt-border|500px]]
 +
 +
====Picture-example====
 +
----
 +
[[File:Networking trb1 configuration multi 1wire via breadboard v1.png|border|class=tlt-border|500px]]
 +
 +
==Output==
 +
Enable the 'ioman.gpio.onewire' service. You can configure this by following the instructions above regarding [[TRB141_1-Wire_Setup/Configuration#1-Wire_activation_commands|1-Wire activation commands]].
 +
 +
We should be able to see all the 1-wire sensor directories and read their values accordingly.
 +
 +
[[File:Networking trb1 configuration cli multi1wire v1.png|border|class=tlt-border|800px]]
 +
 +
[[File:Networking trb1 configuration cli multi1wire output v1.png|border|class=tlt-border|800px]]
 +
 +
28-00000e55f136 = '''31.1 °C'''
 +
 +
28-00000e7dfff9 = '''24.3 °C'''
    
==Summary==
 
==Summary==
 +
 +
In this article we connected and configurated different 1-Wire sensors and learned how to configure the 1-Wire sensor to display data on TRB141 SSH/CLI. Additionally, in this article you can find how different 1-Wire sensors have to be wired/connected to TRB141.
 +
 +
==References==
 +
 +
[[TRB141 Input/Output]]