Difference between revisions of "TSW212 Power Consumption"

From Teltonika Networks Wiki
 
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
 +
'''Averaged''' [[TSW202]] power consumption values in different states of operation are represented in the table(s) below:
 
<table class="nd-othertables_3">
 
<table class="nd-othertables_3">
 
     <tr style="font-weight:bold">
 
     <tr style="font-weight:bold">
Line 118: Line 119:
 
<small><sup><small>1</small></sup> - Data streams between devices were created using iPerf3.</small> <br>
 
<small><sup><small>1</small></sup> - Data streams between devices were created using iPerf3.</small> <br>
 
<small>Power consumption may differ due to testing environment and conditions.</small>
 
<small>Power consumption may differ due to testing environment and conditions.</small>
 +
 +
[[Category:TSW212 Manual]]

Latest revision as of 10:56, 16 August 2024

Main Page > TSW Switches > TSW212 > TSW212 Manual > TSW212 Power Consumption

Averaged TSW202 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
141
1.27
Idle (12 V)
109
1.31
Idle (24 V)
57
1.37
Idle (44 V)
33
1.45
Idle (50 V)
29
1.45
Idle (57 V)
26
1.48


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
236
2.12
2 LAN devices connected + heavy data traffic1 (12 V)
179
2.15
2 LAN devices connected + heavy data traffic1 (24 V)
95
2.28
2 LAN devices connected + heavy data traffic1 (44 V)
54
2.38
2 LAN devices connected + heavy data traffic1 (50 V)
48
2.40
2 LAN devices connected + heavy data traffic1 (57 V)
43
2.45


Test type
Current (mA)
Power consumption (W)
2 SFP and 8 LAN devices connected + heavy data traffic1 (9 V)
506
4.55
2 SFP and 8 LAN devices connected + heavy data traffic1 (12 V)
379
4.55
2 SFP and 8 LAN devices connected + heavy data traffic1 (24 V)
195
4.68
2 SFP and 8 LAN devices connected + heavy data traffic1 (44 V)
111
4.88
2 SFP and 8 LAN devices connected + heavy data traffic1 (50 V)
99
4.95
2 SFP and 8 LAN devices connected + heavy data traffic1 (57 V)
88
5.02


1 - Data streams between devices were created using iPerf3.
Power consumption may differ due to testing environment and conditions.