Difference between revisions of "Template:Networking rut2xx manual modbus modbus tcp table"
From Teltonika Networks Wiki
Line 1: | Line 1: | ||
<table class="nd-mantable"> | <table class="nd-mantable"> | ||
<tr> | <tr> | ||
− | <th> | + | <th>field name</th> |
− | <th> | + | <th>value</th> |
− | <th> | + | <th>description</th> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Enable</td> | <td>Enable</td> | ||
− | <td>yes | no; | + | <td>yes | no; Default: <b>none</b></td> |
− | <td> | + | <td>Toggles Modbus TCP ON or OFF</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Port</td> | <td>Port</td> | ||
− | <td>integer [0..65535]; | + | <td>integer [0..65535]; Default: <b>none</b></td> |
− | <td> | + | <td>Specifies which port will be used for Modbus communication</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Allow Remote Access</td> | <td>Allow Remote Access</td> | ||
− | <td>yes | no; | + | <td>yes | no; Default: <b>no</b></td> |
− | <td>Allows remote Modbus connections by adding an exception to the device's firewall on the port specified in the field above | + | <td>Allows remote Modbus connections by adding an exception to the device's firewall on the port specified in the field above</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Mobile Traffic Usage Logging</td> | <td>Mobile Traffic Usage Logging</td> | ||
− | <td>yes | no; | + | <td>yes | no; Default: <b>no</b></td> |
− | <td>Enables Mobile Traffic Usage Logging (can also be enabled from <b>Status → Mobile Traffic → [[{{{name}}}_Mobile_Traffic#Configuration|Configuration]]</b>). <br> This is required in order to read mobile data usage information from Modbus registers | + | <td>Enables Mobile Traffic Usage Logging (can also be enabled from <b>Status → Mobile Traffic → [[{{{name}}}_Mobile_Traffic#Configuration|Configuration]]</b>). <br> This is required in order to read mobile data usage information from Modbus registers</td> |
</tr> | </tr> | ||
</table> | </table> |
Revision as of 14:20, 5 December 2018
field name | value | description |
---|---|---|
Enable | yes | no; Default: none | Toggles Modbus TCP ON or OFF |
Port | integer [0..65535]; Default: none | Specifies which port will be used for Modbus communication |
Allow Remote Access | yes | no; Default: no | Allows remote Modbus connections by adding an exception to the device's firewall on the port specified in the field above |
Mobile Traffic Usage Logging | yes | no; Default: no | Enables Mobile Traffic Usage Logging (can also be enabled from Status → Mobile Traffic → [[{{{name}}}_Mobile_Traffic#Configuration|Configuration]]). This is required in order to read mobile data usage information from Modbus registers |