Difference between revisions of "RUT955 Input/Output"

From Teltonika Networks Wiki
(16 intermediate revisions by 7 users not shown)
Line 1: Line 1:
{{Template: Networking_rutos_manual_input_output_rut2_rut9
+
{{Template: Networking_rutxxx_manual_input_output
<!------------------------DEVICE----------------------->
+
<!----------------------------DEVICE DETAILS---------------------------->
| name           = RUT955
+
| name                 = RUT955
| series         = RUT9
+
| series               = RUT9xx
<!----------------------SEPARATORS--------------------->
+
| fw_version            = RUT9XX_R_00.06.04
| analog        = 1    <!-- 0 - doesn't have Analog Input; 1 - has Analog Input -->
+
<!--------------------------------STATUS-------------------------------->
| configurableio = 0    <!-- 0 - doesn't have Configurable I/O; 1 - has Configurable I/O -->
+
| file_status          = Networking_rut955_manual_input_output_status_io_status_v1.png
| dualsim       = 1     <!-- 0 - doesn't have Dual SIM; 1 - has Dual SIM -->
+
| file_status_digital  = Networking_rutxxx_manual_input_output_status_custom_label_digital_input_v1.png
| input_volts    = 9-30  <!-- Input voltage range -->
+
| file_status_analog    = Networking_rut955_manual_input_output_status_custom_label_analog_input_v1.png
| juggler_input  = 0    <!-- first input on the I/O Juggler list. 0 - Input; 1 - Configurable I/O; 2 - Passive/Active Input -->
+
<!--------------------------------INPUT--------------------------------->
| mobile        = 1    <!-- 0 - doesn't have mobile; 1 - has mobile -->
+
| file_input_analog    = Networking_rut955_manual_input_output_input_check_analog_v1.png
| wifi          = 1    <!-- 0 - doesn't have wifi; 1 - has wifi -->
+
| file_input_add       = Networking_rutxxx_manual_input_output_input_input_rules_add_new_v1.png
| acl            = 1    <!-- 0 - doesn't have Analog Current Loop; 1 - has Analog Current Loop -->
+
| file_input_config     = Networking_rut955_manual_input_output_input_input_rules_input_configuration_v1.png
| isolated      = 1
+
<!--------------------------------OUTPUT-------------------------------->
| relay          = 1
+
| file_output_config    = Networking_rut955_manual_input_output_output_output_configuration_v1.png
| galvanic      = 1
+
| file_output_on_off    = Networking_rut955_manual_input_output_output_on_off_v1.png
| digitalpassive = 1
+
| file_output_post_get  = Networking_rutxxx_manual_input_output_output_post_get_configuration_v1.png
 +
| file_output_periodic  = Networking_rut955_manual_input_output_output_periodic_control_v1.png
 +
| file_output_scheduler = Networking_rut955_manual_input_output_output_scheduler_v1.png
 
}}
 
}}
 +
 +
===Periodic Control===
 +
----
 +
The '''Periodic control''' section allows you to set up automatic output control rules that trigger output state changes at the specified period or interval.
 +
 +
[[File:Services inputoutput output periodic v2.png]]
 +
 +
<table class="nd-mantable">
 +
    <tr>
 +
        <th>field name</th>
 +
      <th>value</th>
 +
      <th>description</th>
 +
    </tr>
 +
    <tr>
 +
      <td>Enable</td>
 +
      <td>yes | no; Default: '''no'''</td>
 +
      <td>Toggles the rule ON or OFF</td>
 +
    </tr>
 +
    <tr>
 +
      <td>Output</td>
 +
      <td>Digital OC output | Digital Relay output; Default: '''Digital OC output'''</td>
 +
      <td>To which output the rule pertains </td>
 +
    </tr>
 +
    <tr>
 +
    <td>Action</td>
 +
        <td>On | Off; Default: '''On'''</td>
 +
        <td>Periodic action to be taken</td>
 +
    </tr>
 +
    <tr>
 +
    <td>Action timeout</td>
 +
        <td>yes | no; Default: '''no'''</td>
 +
        <td>Activates action timeout. Action timeout specifies whether an action should end after some time. For example, if the specified Action is to turn Digital OC output On and the action triggers, the Action timeout then turns Digital OC output back off after a specified amount of time in seconds specified in this field </td>
 +
    </tr>
 +
    <tr>
 +
    <td>Timeout (sec)</td>
 +
        <td>integer; Default: " "</td>
 +
        <td>Specifies how long the Action timeout is</td>
 +
    </tr>
 +
    <tr>
 +
    <td>Mode</td>
 +
        <td>Fixed | Interval; Default: '''Fixed'''</td>
 +
        <td>'''Fixed''' mode triggers the specified action on a specified day(s), hour and minute. For example, every Sunday at 8:30 AM<br>
 +
 +
'''Interval''' provides you with the possibility to set up an interval after which the same action takes place</td>
 +
    </tr>
 +
</table>
 +
 +
===Scheduler===
 +
----
 +
The '''Scheduler''' lets you configure a schedule of when certain outputs are to be enabled or disabled.
 +
 +
[[File:Services inputoutput output scheduler v2.png]]
 +
 +
==Additional Information==
 +
 +
* Input/Output hardware application examples:
 +
** '''[[RUT955 Connecting relay to open collector output|Connecting relay to open collector output]]'''
 +
** '''[[Inverting RUT955 relay output polarity|Inverting relay output polarity]]'''
 +
** '''[[Using RUT955 Inputs for security applications|Using Inputs for security applications]]'''
 +
** '''[[Current measurement with RUT955 analog input|Current measurement with analog input]]'''
 +
 +
[[Category:RUT955 WebUI]]

Revision as of 14:36, 29 July 2019

Main Page > RUT Routers > RUT955 > RUT955 Manual > RUT955 WebUI > RUT955 Services section > RUT955 Input/Output

Template:Networking rutxxx manual input output

Periodic Control


The Periodic control section allows you to set up automatic output control rules that trigger output state changes at the specified period or interval.

Services inputoutput output periodic v2.png

field name value description
Enable yes | no; Default: no Toggles the rule ON or OFF
Output Digital OC output | Digital Relay output; Default: Digital OC output To which output the rule pertains
Action On | Off; Default: On Periodic action to be taken
Action timeout yes | no; Default: no Activates action timeout. Action timeout specifies whether an action should end after some time. For example, if the specified Action is to turn Digital OC output On and the action triggers, the Action timeout then turns Digital OC output back off after a specified amount of time in seconds specified in this field
Timeout (sec) integer; Default: " " Specifies how long the Action timeout is
Mode Fixed | Interval; Default: Fixed Fixed mode triggers the specified action on a specified day(s), hour and minute. For example, every Sunday at 8:30 AM
Interval provides you with the possibility to set up an interval after which the same action takes place

Scheduler


The Scheduler lets you configure a schedule of when certain outputs are to be enabled or disabled.

Services inputoutput output scheduler v2.png

Additional Information