Difference between revisions of "TSW100 Power Consumption"
From Teltonika Networks Wiki
m (Protected "TSW100 Power Consumption" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite))) |
(Created page with "{{Template: Networking_device_faq_power_consumption | name = TSW100 }}") |
(No difference)
|
Revision as of 15:04, 14 July 2020
Main Page > TSW Switches > TSW100 > TSW100 Manual > TSW100 Power ConsumptionTSW100 power consumption values in different states of operation are represented in the table(s) below:
Test type | ||
---|---|---|
Idle (12 V) | ||
Idle (24 V) | ||
Idle (44 V) | ||
Idle (50 V) | ||
Idle (57 V) |
Test type | ||
---|---|---|
5 LAN devices connected + heavy data traffic1 (12 V) | ||
5 LAN devices connected + heavy data traffic1 (24 V) | ||
5 LAN devices connected + heavy data traffic1 (44 V) | ||
5 LAN devices connected + heavy data traffic1 (50 V) | ||
5 LAN devices connected + heavy data traffic1 (57 V) |
Test type | ||
---|---|---|
4 PoE devices connected + heavy data traffic1 (44 V) | ||
4 PoE devices connected + heavy data traffic1 (50 V) | ||
4 PoE devices connected + heavy data traffic1 (57 V) |
Test type | ||
---|---|---|
4 PoE dummy loads connected (30 W each) (44 V) | ||
4 PoE dummy loads connected (30 W each) (50 V) | ||
4 PoE dummy loads connected (30 W each) (57 V) |
1 - Data streams between devices were created using iPerf.
Power consumption may differ due to connected devices, testing environment and conditions.