In this guide, Modbus TCP master MQTT Gateway function will be configured with two different types of MQTT Brokers. First using third-party MQTT Broker services (in this example ''Flespi.io''). Second, using another router as MQTT Broker. Two RUT955 routers will be used as Modbus TCP Master and Slave, and the PC acts as MQTT Publisher and Subscriber.
This article contains instructions on how to send M-Bus data to the server using various protocols.


==Configuration overview & prerequisites==
==Configuration overview & prerequisites==
*Two RUT955 routers - one acts as Modbus TCP Master, another as Modbus TCP Slave
Before we begin, let's take a look at the configuration that we are attempting to achieve and the prerequisites that make it possible.
*Flespi.io account to act as an MQTT Broker/Publisher/Subscriber (for first configuration example)
*RUT with a Public IP address to act as MQTT Broker (for second configuration example)
*An end device (PC, Laptop) to act as MQTT Subscriber/Publisher (for second configuration example)


==Configuration using flespi.io as MQTT Broker==
'''Prerequisites''':
[[File:Networking Topology MQTT MODBUS flespi configuration v1.png|center|class=tlt-border|800x800px]]
* TRB143;
* M-Bus device;
* Server;
* An end device (PC, Laptop, Tablet, Smartphone) for configuration;


===Configuring RUT955 Modbus TCP Slave===
{{Template:Networking_rutos_manual_basic_advanced_webui_disclaimer
| series = RUTX
}}
 
==Adding M-Bus devices==
The '''[[TRB143_M-Bus|M-Bus Settings]]''' section is used to configure the general service functionality. To set up a new M-Bus instance, go to '''Services → M-Bus → Client'''. Add a new device to the configuration press [[File:Add Button.png|60x90px]] button which is shown below.
 
[[File:Mbus adding new device.png||border|class=tlt-border]]
 
===Device configuration===
----
----
Go to '''Services → Modbus → Modbus TCP Slave''':
You will be granted to a new window. Configure your M-Bus device accordingly:


#Check '''Enable'''
# '''Name''': Enter the desired name of the M-Bus device
#Enter port that will be used, in this example 502 will be used
# '''Address type''': select which M-Bus address will be used
#Enter device ID
# '''Primary/Secondary address''': specify M-Bus address
#Press '''Save & Apply'''
[[File:Networking_MQTT_MODBUS_flespi_configuration_slave1_v1.png|border|class=tlt-border|1044x1044px]]


''*In this configuration LAN port is used hence “Allow Remote Access” is not needed''
[[File:Mbus adding new device configuration v3.png|border|class=tlt-border]]


''Modbus TCP Slave RUT955 is now configured''.
Test if the M-Bus device is reachable by a specified primary/secondary address. To do so click on [[File:Ping_device_option_mbus.png|110x110px]]. You might get on of two outputs:


===Configuring RUT955 Modbus TCP Master===
* If you have specified correct primary/secondary address, you will receive:
----
[[File:Mbus device pingable v2.png|border|class=tlt-border|300px]]
Go to '''Services → Modbus → Modbus TCP Master'''


#Press '''Add'''
* If you have specified incorrect primary/secondary address, you will receive (if you do not know what address should be used, refer to the Scanning for available M-Bus devices (PRIDET URL) secion:
# Check '''Enable'''
[[File:Mbus device not pingable v2.png|border|class=tlt-border|300px]]
# Enter the name for the slave device
# Slave ID must match with the previously configured Slave device ID
#Enter the IP address of the Modbus TCP Slave device
#Chose same Port as in Slave device - 502
#Enter Period in seconds, how often requests will be sent to the Slave device
#Enter new request name and press '''Add''' in Requests configurations
#Choose Data type and Function, enter First register/coil/input to be read or written and Register count. You can name each individual configuration, and then select enable on configurations that you want to use. In this example, register to get Routers name is used.
#Press the Test button in Request Configuration Testing to see if the Slave device responds to requests, a response similar to the image below should be shown.
#Press Save & Apply
''List of available Modbus parameters can be found [https://wiki.teltonika-networks.com/view/RUT955_Monitoring_via_Modbus#Get_Parameters here]''


[[File:Networking_MQTT_MODBUS_flespi_configuration_master_add_v1.png|alt=|border|class=tlt-border|1007x1007px]]
Once finished, save the configuration by clicking [[File:Savenapply button.png|Savenapply button.png]].


[[File:Networking MQTT MODBUS flespi configuration master afteradd step 234567 v2.png|border|class=tlt-border|1006x1006px]]
===Scanning for available M-Bus devices===
----


[[File:Networking MQTT MODBUS flespi configuration master req testing v3.png|border|class=tlt-border|1007x1007px]]
If you are not sure what address your M-Bus devices have, you can try scanning for the available M-Bus devices. To do so click on [[File:Scan button.png]] button.


===Configuring Flespi.io MQTT Broker===
====Scan settings====
----
----
#Log in or create an account on https://flespi.io
You will be granted to a new window. Configure scan settings accordingly:


[[File:Networking MQTT Modbus flespiio login.png|border|class=tlt-border|842x842px]]
# '''Scan type''': select which M-Bus address will be scanned
# '''Scan range''': From what M-Bus address scanning will start and M-Bus address until scanning will be performed.
[[File:Mbus scan.png|border|class=tlt-border]]


Once logged in:
To start the scan click on [[File:Start scan button.png]] button.


#Navigate to MQTT Board on the left side of the screen and press it.                                         
====Found devices====
#On the right-hand panel, top right corner, next to the name of the MQTT board, press the cogwheel-looking icon to open ''Connection Settings''
#In the opened window, press "Get flespi token" to generate a username
#Enter Client name
#Copy Host address
#Copy Username
#Create a password
#Press Save
[[File:Networking MQTT modbus fespi Connection settings v1.png|border|class=tlt-border|544x544px]] [[File:Networking MQTT Modbus flespi board.png|border|class=tlt-border|544x544px]] 
 
=== Configuring MQTT Gateway on RUT955 Modbus TCP Master===
----
----
Open routers WebUI and navigate to '''Services → Modbus → MQTT Gateway'''
Once the scan is finished you should see the list of M-Bus devices that TRB143 were able to find:


#Select Enable
[[File:Mbus scanned devices add.png|border|class=tlt-border]]
#Enter Host (copied from flespi connection settings without 'wss://' and port)
#Enter Username (Copied from flespi Connection settings generated token)
#Enter Password


[[File:Networking MQTT Modbus Rut configuration Mqtt gateway v1.png|border|class=tlt-border|1058x1058px]]
You can either [[File:Pencil2.png]] '''(1)''' M-Bus devices primary address or [[File:Add Button.png|60x90px]] '''(2)''' to the M-Bus devices list.


''You can change Request and Response topics that you will have to publish and subscribe to get information from Modbus TCP Master through MQTT Gateway, but for this example, they are left on default topics''
==Gathering M-Bus data==


===Message format for MQTT publisher===
If the device successfully added to the list, under the General settings you should see that the Status changes to <span style="color:green">Active</span>.
----
The format is in the text - heavier and slower, but less difficult to edit.
{| class="wikitable"
|1.  Format version
|'''0'''
|-
|2. Cookie
|from '''0''' to '''2<sup>64</sup> -1'''
|-
|3. IP Type
|'''0''' - IPv4; '''1''' - IPv6; '''2''' - hostname
|-
|4. IP
|IPv6 must be in full format (for example: '''2001:0db8:0000:0000:0000:8a2e:0370:7334''')
|-
|5. Port
|Port number (for example: '''502''')
|-
|6. Timeout in seconds (time to wait for response)
|from '''1''' to '''999'''
|-
|7. Slave ID - Indicates to which slave request is sent
|from '''1''' to '''255'''
|-
|8. Function
|'''3''' - read registers; '''6''' - write single register; '''16''' - write multiple registers
|-
|9. Number of the first register from which information will be read or written
|from '''1''' to '''65535'''
|-
|10. Registry value
|If function is 3 - from '''1''' to '''123''' (first register + registry value can not go out of range);
If function is 6 - from '''0''' to '''65535'''


If function is 16 - from '''1''' to '''123''' (first register + registry value can not go out of range), Registry values separated by commas without spaces. Example.: '''1,2,3,654,21,789'''. There has to be as many values, as specified number of registers, and each value must be between '''0''' and '''65535'''. If number of registries is 0, there should be '''no registry values'''
[[File:Mbus status active v2.png|border|class=tlt-border]]
|}
[[File:Networking MQTT modbus message format publisher v1.png|border|class=tlt-border]]


====Examples====
===Data collecting groups===
----
----
{| class="wikitable"
To reach data collecting groups configuration press [[File:Pencil2.png]] button. [[File:Add Button.png|60x90px]] button lets you to create a new instance.
|Setting relay (on) (Relay address is 202, which means 'Number of first register will be 203)
 
|'''0 65432 0 192.168.1.1 502 5 1 6 203 1'''
[[File:Mbus data collect overview.png|border|class=tlt-border]]
|-
|Getting uptime
|'''0 65432 0 192.168.1.1 502 5 1 3 2 2'''
|}


===Testing MQTT Publisher and Subscriber on flespi.io===
====Data collecting group instance====
----
----
Log in and navigate to MQTT Board on https://flespi.io


Add a Subscriber:
Each data collection group contains the following information. Configure device accordingly:


#Press '''''<nowiki/>'+'''''' button on the top right corner
# '''Enabled''': on
#Select '''''<nowiki/>'Subscriber''''''
# '''Name''': desired name of the instance
# In the topic field enter '''''<nowiki/>'response''''''
# '''Period''': desired time duration between data retrievals
#Press '''''<nowiki/>'Subscribe'''''' button
# '''Data type''': desired data type to process the received data. Depending on your needs you can select between 5 different data types: '''JSON, XML, ASCII, Hexadecimal''' and '''Binary'''.


[[File:Networking MQTT Modbus flespi subscriber config1 v1.png|border|class=tlt-border]]            [[File:Networking MQTT Modbus flespi subscriber config2 v1.png|border|class=tlt-border]]
[[File:Mbus data collect group v2.png|border|class=tlt-border]]


Add a Publisher:
You can check if your configuration works accordingly by pressing the [[File:Mbus test button.png]] button. You should see the data in a pop-up field:


#Press '''''<nowiki/>'+'''''' button on the top right corner
[[File:Mbus TEST output.png|border|class=tlt-border]]
#Select '''''<nowiki/>'Publisher''''''
# In the topic field enter '''''<nowiki/>'request''''''
#In the message field enter message, for this example '''''<nowiki/>'Getting uptime'''''' is used
#Press '''''<nowiki/>'Publish'''''' button


[[File:Networking MQTT Modbus flespi publisher config1 v1.png|border|class=tlt-border|434x434px]]          [[File:Networking MQTT Modbus flespi publisher config2 v1.png|border|class=tlt-border|365x365px]]
====Group values====
----
To reach group values configuration press [[File:Pencil2.png]] button:


[[File:Mbus edit group values.png|border|class=tlt-border]]


Check the response in the '''''<nowiki/>'Subscriber'''''' tab, you should receive a message similar to the one below.
There you can adjust additional settings:


# '''Enable''': Enable/disable data group value.
# '''FCB toggle''': FCB (Frame Count-Bit), one-bit counter for reliable server-client communication.
# '''Manufacturer information''': Select to include manufacturer information in the payload.
# '''Selected parameters''': Select to include the all parameters saved from device, or a custom subset of them. If the custom is selected you can specify '''frame''', '''record''' numbers and also a '''paramater'''


[[File:Networking MQTT Modbus flespi Response v2.png|border|class=tlt-border|931x931px]]
[[File:Mbus device groupsa.png|border|class=tlt-border]]


When the value climbs over 65535 the counter resets and the value held by the first register increases by '''1'''. So one way to interpret the results would be to multiply the value in the first register by '''2<sup>16</sup>''' and add it to the value of the second register. In this example: '''9 * 65536 + 3502 = 593326s''' or '''6 days 20 hours 48 minutes and 46 seconds.'''


''This Means that MQTT Gateway on Modbus TCP Master router is working correctly and Modbus TCP Slave receives requests.''
==Sending data to the server==
The '''[[TRB143_Data_to_Server|Data to Server]]''' feature provides you with the possibility to set up data senders that collect data from various sources and periodically send it to remote servers. This section will walk you through configuring the Data to Server to send M-Bus data to the desired HTTP or MQTT server.


==Configuration using a router as MQTT Broker==
===Data to Server configuration===
----
To set up Data to Server, navigate to Services → Data to Server. Enter desired name of the instnace and hit [[File:Add Button.png|60x90px]] button which is shown below.


[[File:Networking Topology MQTT MODBUS RUTbroker configuration v1.png|987x987px]]
[[File:Mbus data to server create.png|border|class=tlt-border]]


===Configuring Modbus TCP Master, MQTT Gateway MQTT Broker on RUT240, and MQTT Publisher/Subscriber on PC===
===Data configuration===
----
----
''The same configuration will be used for Modbus TCP Master and Slave RUT955 routers as in the previous example, only settings in Modbus TCP Master router RUT955 will be changed to match MQTT Broker on RUT240 router''


Navigate to '''Services → Modbus  MQTT Gateway'''
Each data collection group contains the following information. Configure device accordingly:
 
# '''Name''': desired name of the instance
# '''Type''': M-Bus data
# '''Format''': custom or JSON depending on a need.
 
[[File:Mbus data to server configuration.png|border|class=tlt-border]]


#'''Enable'''
# Host: '''Enter Public IP address of MQTT Broker (RUT240)'''
#Username: '''N/A'''
#Password: '''N/A'''
#Press '''Save & Apply'''


[[File:Networking MQTT Modbus MQTT gateway config v1.png|border|class=tlt-border|1090x1090px]]
Once finished configuring Data configuration tab click on [[File:Mbus data to server collection edit.png|160x160px]] button.


===Configuring RUT MQTT Broker===
===Collection configuration===
----
----


Navigate to '''Services → MQTT → Broker'''
[[File:Mbus data to server collection configuration.png|border|class=tlt-border]]


#Select '''Enable'''
Once finished configuring Collection configuration tab click on [[File:Mbus data to server server button.png|160x160px]] button.
#Check '''Enable Remote Access'''
#Press '''Save & Apply'''


[[File:Networking MQTT Modbus MQTT Broker RUTos config v1.png|border|class=tlt-border|1079x1079px]]
===Server configuration===
----
This section contains information on how to configure MQTT and HTTP servers information.


===Testing MQTT Gateway===
====HTTP configuration====
----
----


For testing purposes, two terminal windows will be used on the same PC.  
# '''Type''': HTTP
# '''Server address''': desired server address
 
'''Note''': not specified fields are optional.
 
[[File:Mbus data to server HTTP configuration.png|border|class=tlt-border]]


''To get Ubuntu terminal  on Windows 10/11, refer to the following link for instructions:'' https://tutorials.ubuntu.com/tutorial/tutorial-ubuntu-on-windows#0
====MQTT configuration====
----


*Open first terminal, which will act as '''Subscriber'''. Type in:
# '''Type''': MQTT
# '''Server address''': desired server address
# '''Topic''': MQTT topic to be used for publishing the data.


<blockquote>''mosquitto_sub -h [Host_address] -p [Port] -t [Topic]''</blockquote>[[File:Networking MQTT Modbus Subscriber in terminal v1.png|border|class=tlt-border]]
'''Note''': not specified fields are optional.


*Open second terminal, which will act as '''Publisher.''' Type in:
[[File:Mbus data to server MQTT configuration.png|border|class=tlt-border]]


<blockquote>''mosquitto_pub -h [Host_address] -p [Port] -m [‘Message’] -t [Topic]''</blockquote>[[File:Networking MQTT Modbus Publisher testing v1.png|border|class=tlt-border]]
Once finished configuring Server configuration tab click on [[File:Savenapply button.png|Savenapply button.png]] button.


*On the first window - '''Subscriber''', a response should appear
===Results===
----


[[File:Networking MQTT Modbus Subscriber response ubuntu v1.png|border|class=tlt-border]]
[[File:Mbus data received v2.png|border|class=tlt-border]]


==See Also==
'''Note''': received data formating depends on the settings you apply under Data to Server and M-Bus configurations.
*[[Modbus Master RutOS configuration example]]
*[[RUT955 Monitoring via Modbus#Get Parameters]]

Latest revision as of 07:20, 25 October 2024

The information on this page is updated in accordance with the 00.07.08 firmware version .

Summary

This article contains instructions on how to send M-Bus data to the server using various protocols.

Configuration overview & prerequisites

Before we begin, let's take a look at the configuration that we are attempting to achieve and the prerequisites that make it possible.

Prerequisites:

  • TRB143;
  • M-Bus device;
  • Server;
  • An end device (PC, Laptop, Tablet, Smartphone) for configuration;

If you're having trouble finding this page or some of the parameters described here on your device's WebUI, you should turn on "Advanced WebUI" mode. You can do that by clicking the "Advanced" button, located at the top of the WebUI.

Adding M-Bus devices

The M-Bus Settings section is used to configure the general service functionality. To set up a new M-Bus instance, go to Services → M-Bus → Client. Add a new device to the configuration press button which is shown below.

Device configuration


You will be granted to a new window. Configure your M-Bus device accordingly:

  1. Name: Enter the desired name of the M-Bus device
  2. Address type: select which M-Bus address will be used
  3. Primary/Secondary address: specify M-Bus address

Test if the M-Bus device is reachable by a specified primary/secondary address. To do so click on . You might get on of two outputs:

  • If you have specified correct primary/secondary address, you will receive:

  • If you have specified incorrect primary/secondary address, you will receive (if you do not know what address should be used, refer to the Scanning for available M-Bus devices (PRIDET URL) secion:

Once finished, save the configuration by clicking Savenapply button.png.

Scanning for available M-Bus devices


If you are not sure what address your M-Bus devices have, you can try scanning for the available M-Bus devices. To do so click on button.

Scan settings


You will be granted to a new window. Configure scan settings accordingly:

  1. Scan type: select which M-Bus address will be scanned
  2. Scan range: From what M-Bus address scanning will start and M-Bus address until scanning will be performed.

To start the scan click on button.

Found devices


Once the scan is finished you should see the list of M-Bus devices that TRB143 were able to find:

You can either (1) M-Bus devices primary address or (2) to the M-Bus devices list.

Gathering M-Bus data

If the device successfully added to the list, under the General settings you should see that the Status changes to Active.

Data collecting groups


To reach data collecting groups configuration press button. button lets you to create a new instance.

Data collecting group instance


Each data collection group contains the following information. Configure device accordingly:

  1. Enabled: on
  2. Name: desired name of the instance
  3. Period: desired time duration between data retrievals
  4. Data type: desired data type to process the received data. Depending on your needs you can select between 5 different data types: JSON, XML, ASCII, Hexadecimal and Binary.

You can check if your configuration works accordingly by pressing the button. You should see the data in a pop-up field:

Group values


To reach group values configuration press button:

There you can adjust additional settings:

  1. Enable: Enable/disable data group value.
  2. FCB toggle: FCB (Frame Count-Bit), one-bit counter for reliable server-client communication.
  3. Manufacturer information: Select to include manufacturer information in the payload.
  4. Selected parameters: Select to include the all parameters saved from device, or a custom subset of them. If the custom is selected you can specify frame, record numbers and also a paramater


Sending data to the server

The Data to Server feature provides you with the possibility to set up data senders that collect data from various sources and periodically send it to remote servers. This section will walk you through configuring the Data to Server to send M-Bus data to the desired HTTP or MQTT server.

Data to Server configuration


To set up Data to Server, navigate to Services → Data to Server. Enter desired name of the instnace and hit button which is shown below.

Data configuration


Each data collection group contains the following information. Configure device accordingly:

  1. Name: desired name of the instance
  2. Type: M-Bus data
  3. Format: custom or JSON depending on a need.


Once finished configuring Data configuration tab click on button.

Collection configuration


Once finished configuring Collection configuration tab click on button.

Server configuration


This section contains information on how to configure MQTT and HTTP servers information.

HTTP configuration


  1. Type: HTTP
  2. Server address: desired server address

Note: not specified fields are optional.

MQTT configuration


  1. Type: MQTT
  2. Server address: desired server address
  3. Topic: MQTT topic to be used for publishing the data.

Note: not specified fields are optional.

Once finished configuring Server configuration tab click on Savenapply button.png button.

Results


Note: received data formating depends on the settings you apply under Data to Server and M-Bus configurations.