Difference between revisions of "Domnev"

From Teltonika Networks Wiki
 
(3 intermediate revisions by the same user not shown)
Line 1: Line 1:
<p style="color:red">The information on this page is updated in accordance with the [https://wiki.teltonika-networks.com/view/FW_%26_SDK_Downloads'''00.07.4'''] firmware version .</p>
+
<p style="color:red">The information on this page is updated in accordance with the [https://wiki.teltonika-networks.com/view/FW_%26_SDK_Downloads'''00.07.08'''] firmware version .</p>
 
__TOC__
 
__TOC__
 
==Summary==
 
==Summary==
Line 22: Line 22:
 
To add a new device to the configuration press [[File:Add Button.png|60x90px]] button which is shown below.
 
To add a new device to the configuration press [[File:Add Button.png|60x90px]] button which is shown below.
  
[[File:Mbus adding new device.png||border|class=tlt-border|center]]
+
[[File:Mbus adding new device.png||border|class=tlt-border]]
  
Configure your device accordingly:
+
===Device configuration===
 +
----
 +
You will be granted to a new window. Configure your M-Bus device accordingly:
  
 
# '''Name''': Enter the desired name of the M-Bus device
 
# '''Name''': Enter the desired name of the M-Bus device
Line 30: Line 32:
 
# '''Primary/Secondary address''': specify M-Bus address
 
# '''Primary/Secondary address''': specify M-Bus address
  
[[File:Mbus adding new device configuration v3.png|border|class=tlt-border|center]]
+
[[File:Mbus adding new device configuration v3.png|border|class=tlt-border]]
  
Test if the M-Bus device is reachblae by specify address. To do so click on [[File:Ping_device_option_mbus.png|110x110px]]. You migth get two outputs:
+
Test if the M-Bus device is reachable by a specified primary/secondary address. To do so click on [[File:Ping_device_option_mbus.png|110x110px]]. You might get on of two outputs:
  
[[File:Mbus device pingable v2.png|border|class=tlt-border|221×82px]]
+
* If you have specified correct primary/secondary address, you will receive:
 +
[[File:Mbus device pingable v2.png|border|class=tlt-border|300px]]
  
[[File:Mbus device not pingable v2.png|border|class=tlt-border|221×82px]]
+
* If you have specified incorrect primary/secondary address, you will receive (if you do not know what address should be used, refer to the Scanning for available M-Bus devices (PRIDET URL) secion:
 +
[[File:Mbus device not pingable v2.png|border|class=tlt-border|300px]]
  
 +
Once finished, save the configuration by clicking [[File:Savenapply button.png|Savenapply button.png]].
 +
 +
===Scanning for available M-Bus devices===
 +
----
 +
 +
If you are not sure what address your M-Bus devices have, you can try scanning for the available M-Bus devices. To do so click on [[File:Scan button.png]] button.
 +
 +
====Scan settings====
 +
----
 +
You will be granted to a new window. Configure scan settings accordingly:
 +
 +
# '''Scan type''': select which M-Bus address will be scanned
 +
# '''Scan range''': From what M-Bus address scanning will start and M-Bus address until scanning will be performed.
 +
[[File:Mbus scan.png|border|class=tlt-border]]
 +
 +
To start the scan click on [[File:Start scan button.png]] button.
 +
 +
====Found devices====
 +
----
 +
Once the scan is finished you should see the list of M-Bus devices that TRB143 were able to find:
 +
 +
[[File:Mbus scanned devices add.png|border|class=tlt-border]]
 +
 +
You can either [[File:Pencil2.png]] '''(1)''' M-Bus devices primary address or [[File:Add Button.png|60x90px]] '''(2)''' to the M-Bus devices list.
 +
 +
==Gathering M-Bus data==
 +
 +
If the device successfully added to the list, under the General settings you should see that the Status changes to <span style="color:green">Active</span>.
 +
 +
[[File:Mbus status active v2.png|border|class=tlt-border]]
 +
 +
===Data collecting groups===
 +
----
 +
To reach data collecting groups configuration press [[File:Pencil2.png]] button. [[File:Add Button.png|60x90px]] button lets you to create a new instance.
 +
 +
[[File:Mbus data collect overview.png|border|class=tlt-border]]
 +
 +
====Data collecting group instance====
 +
----
 +
 +
Each data collection group contains the following information. Configure device accordingly:
 +
 +
# '''Enabled''': on
 +
# '''Name''': desired name of the instance
 +
# '''Period''': desired time duration between data retrievals
 +
# '''Data type''': desired data type to process the received data. You can choose from JSON, XML, ASCII, Hexadecimal and Binary formats.
 +
 +
You can check if your configuration works accordingly by pressing the [[File:Mbus test button.png]] button. You should see the data in a pop-up field.
 +
 +
[[File:Mbus data collect group v2.png|border|class=tlt-border]]
  
  
 
==See Also==
 
==See Also==
*[[RUT955 Monitoring via Modbus#Get Parameters]]
+
 
*[[RUT955_Modbus#MQTT_Gateway|MQTT Gateway and Modbus]]
 
 
==External links==
 
==External links==
 
[https://flespi.io/#/ Flespi.io]
 
[https://flespi.io/#/ Flespi.io]

Latest revision as of 14:06, 24 July 2024

The information on this page is updated in accordance with the 00.07.08 firmware version .

Summary

This article contains instructions on how to send M-Bus data to the server using various protocols.

Configuration overview & prerequisites

Before we begin, let's take a look at the configuration that we are attempting to achieve and the prerequisites that make it possible.

Prerequisites:

  • TRB143;
  • M-Bus device;
  • Server;
  • An end device (PC, Laptop, Tablet, Smartphone) for configuration;


If you're having trouble finding this page or some of the parameters described here on your device's WebUI, you should turn on "Advanced WebUI" mode. You can do that by clicking the "Advanced" button, located at the top of the WebUI.

Networking rutos manual webui basic advanced mode 75.gif


Adding M-Bus devices

To add a new device to the configuration press Add Button.png button which is shown below.

Mbus adding new device.png

Device configuration


You will be granted to a new window. Configure your M-Bus device accordingly:

  1. Name: Enter the desired name of the M-Bus device
  2. Address type: select which M-Bus address will be used
  3. Primary/Secondary address: specify M-Bus address

Mbus adding new device configuration v3.png

Test if the M-Bus device is reachable by a specified primary/secondary address. To do so click on Ping device option mbus.png. You might get on of two outputs:

  • If you have specified correct primary/secondary address, you will receive:

Mbus device pingable v2.png

  • If you have specified incorrect primary/secondary address, you will receive (if you do not know what address should be used, refer to the Scanning for available M-Bus devices (PRIDET URL) secion:

Mbus device not pingable v2.png

Once finished, save the configuration by clicking Savenapply button.png.

Scanning for available M-Bus devices


If you are not sure what address your M-Bus devices have, you can try scanning for the available M-Bus devices. To do so click on Scan button.png button.

Scan settings


You will be granted to a new window. Configure scan settings accordingly:

  1. Scan type: select which M-Bus address will be scanned
  2. Scan range: From what M-Bus address scanning will start and M-Bus address until scanning will be performed.

Mbus scan.png

To start the scan click on Start scan button.png button.

Found devices


Once the scan is finished you should see the list of M-Bus devices that TRB143 were able to find:

Mbus scanned devices add.png

You can either Pencil2.png (1) M-Bus devices primary address or Add Button.png (2) to the M-Bus devices list.

Gathering M-Bus data

If the device successfully added to the list, under the General settings you should see that the Status changes to Active.

Mbus status active v2.png

Data collecting groups


To reach data collecting groups configuration press Pencil2.png button. Add Button.png button lets you to create a new instance.

Mbus data collect overview.png

Data collecting group instance


Each data collection group contains the following information. Configure device accordingly:

  1. Enabled: on
  2. Name: desired name of the instance
  3. Period: desired time duration between data retrievals
  4. Data type: desired data type to process the received data. You can choose from JSON, XML, ASCII, Hexadecimal and Binary formats.

You can check if your configuration works accordingly by pressing the Mbus test button.png button. You should see the data in a pop-up field.

Mbus data collect group v2.png