Template:Networking device manual powering options passive poe: Difference between revisions
m (Protected "Template:Networking device manual powering options passive poe" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite))) |
No edit summary |
||
(53 intermediate revisions by 7 users not shown) | |||
Line 1: | Line 1: | ||
==Passive PoE== | ==Passive PoE== | ||
The device may also be powered by an Ethernet cable via the <b>{{#ifeq:{{{series}}}|RUT2xx|LAN|LAN1}}</b> port: | The device may also be powered by an Ethernet cable via the <b>{{#ifeq:{{{series}}}|RUT2xx|LAN|{{#ifeq:{{{series}}}|TRB14x|LAN|LAN1}}}}</b> port (<b>{{#switch:{{{series}}}|RUTX|RUTM|RUTC=9-50 VDC|RUT206=9-57 VDC|RUT30X=7-30 VDC|TCR1=12 VDC|#default=9-30 VDC}}</b>):<br> | ||
{{#ifeq:{{{series}}}|TRB14x | |||
| | |||
|'''(Do not use in other ports!)''' | |||
}} | |||
[[File:{{{file_lan1}}}|{{{size_lan1}}}px]] | [[File:{{{file_lan1}}}|{{{size_lan1}}}px]] | ||
Line 7: | Line 11: | ||
<font size="-1"> | <font size="-1"> | ||
<ul> | <ul> | ||
<li>The device is <b>NOT COMPLIANT</b> with the IEEE 802.3af-2003 standard: powering the device from an IEEE 802.3af-2003 power supply <b>will damage the device</b> as it is not rated for input voltages of the PoE standard.</li> | {{#switch:{{{name}}} | ||
<li>The device is <b>NOT COMPLIANT</b> with the IEEE 802.3at standard: it cannot power other devices over Ethernet.</li> | | RUTC50 = <li>{{{name}}} devices support PPoE <b>FROM</b> HW revision 0303 and batch number 007.</li> | ||
| TRB140 = <li>{{{name}}} devices support PPoE <b>FROM</b> HW revision 0004 and batch number 005.</li> | |||
| #default =}} | |||
<li>{{#switch:{{{series}}}|RUT206=|#default=The device is <b>NOT COMPLIANT</b> with the IEEE 802.3af-2003 standard: powering the device from an IEEE 802.3af-2003 power supply <b>will damage the device</b> as it is not rated for input voltages of the PoE standard.}}</li> | |||
<li>{{#switch:{{{series}}}|RUT206=|#default=The device is <b>NOT COMPLIANT</b> with the IEEE 802.3at standard: it cannot power other devices over Ethernet.}}</li> | |||
<li>{{#switch:{{{series}}}|RUTM|RUT2M|RUT9M=The device is <b>NOT COMPLIANT</b> with the IEEE 802.3bt standard.||}}</li> | |||
</ul> | </ul> | ||
</font> | </font> | ||
{{Template: | {{#switch:{{{series}}} | ||
|RUTX|RUTM={{Template: networking_rutx_device_manual_powering_options_passive_poe_table}} | |||
|RUT206={{Template: networking_rut206_manual_powering_options_passive_poe_table}} | |||
|#default={{Template: networking_device_manual_powering_options_passive_poe_table}} | |||
}} |
Latest revision as of 13:44, 22 November 2024
Passive PoE
The device may also be powered by an Ethernet cable via the LAN1 port (9-30 VDC):
(Do not use in other ports!)
[[File:{{{file_lan1}}}|{{{size_lan1}}}px]]
- The device is NOT COMPLIANT with the IEEE 802.3af-2003 standard: powering the device from an IEEE 802.3af-2003 power supply will damage the device as it is not rated for input voltages of the PoE standard.
- The device is NOT COMPLIANT with the IEEE 802.3at standard: it cannot power other devices over Ethernet.