<b>Inputs</b> and <b>outputs</b> are used for monitoring and controlling a connected device or receiving signals from that device in order to trigger certain events.
+
This article contains instructions on how to send M-Bus data to the server using various protocols.
  
==Configuration overview and prerequisites==
+
==Configuration overview & prerequisites==
 +
Before we begin, let's take a look at the configuration that we are attempting to achieve and the prerequisites that make it possible.
  
Before we begin, let's overview the configuration that we are attempting to achieve and the prerequisites that make it possible.
+
'''Prerequisites''':
 +
* TRB143;
 +
* M-Bus device;
 +
* Server;
 +
* An end device (PC, Laptop, Tablet, Smartphone) for configuration;
  
'''Prerequisites''':
 
* Two RUT955 routers (one of them with an active data connection)
 
* An end device (PC, Laptop, Tablet, Smartphone)
 
* Router's LANs should be in different subnet
 
  
==Router configuration==
+
{{Template:Networking_rutos_manual_basic_advanced_webui_disclaimer
 +
| series = RUTX
 +
}}
  
If you have familiarized yourself with the configuration scheme and have all of the devices in order, you can start configuring your routers using instructions provided in this section.
 
  
If you're having trouble finding this page or some of the parameters described here on your device's WebUI, you should >turn on "Advanced WebUI" mode</b>. . You can do that by clicking the "Basic" button under "Mode", which is located at the top-right corner of the WebUI.
+
==Adding M-Bus devices==
[[File:Basic WebUI Advanced.gif|border|center|class=tlt-border|1004x1004px]]
+
To add a new device to the configuration press [[File:Add Button.png|60x90px]] button which is shown below.
  
==Via SMS==
+
[[File:Mbus adding new device.png||border|class=tlt-border]]
  
===RUT 1===
+
===Device configuration===
 
----
 
----
====Mobile Utilities configuration====
+
You will be granted to a new window. Configure your M-Bus device accordingly:
  
* Log into Router 1 WebUI;
+
# '''Name''': Enter the desired name of the M-Bus device
* Go to the '''Services → Mobile Utilities → SMS Utilities''' page;
+
# '''Address type''': select which M-Bus address will be used
* Enter desired SMS text command ('''1''') and select action ('''2''');
+
# '''Primary/Secondary address''': specify M-Bus address
* Add new instance ('''3''');
 
  
[[File:SMS utils add.png|border|center|class=tlt-border|1004x1004px]]
+
[[File:Mbus adding new device configuration v3.png|border|class=tlt-border]]
  
After this you should redirected to configuration page for that rule:
+
Test if the M-Bus device is reachable by a specified primary/secondary address. To do so click on [[File:Ping_device_option_mbus.png|110x110px]]. You might get on of two outputs:
[[File:SMS utils SMS config.png|border|center|class=tlt-border|1004x1004px]]
 
  
# '''Open General''' tab;
+
* In case of correct M-Bus address, you will receive:
# Check '''Enable''';
+
[[File:Mbus device pingable v2.png|border|class=tlt-border|300px]]
# Action - '''Change I/O state''';
 
# State - '''High'''
 
# SMS text - Enter your desired '''SMS text''';
 
# Save and apply changes;
 
  
'''Note:''' Not marked fields can be left as default.
+
* In case of incorrect M-Bus address, you will receive:
===RUT 2===
+
[[File:Mbus device not pingable v2.png|border|class=tlt-border|300px]]
----
 
====I/O Juggler configuration====
 
The I/O Juggler is a feature that provides the possibility to create automated rules that perform certain actions based on Input state changes and other conditions. You can learn more about it [[RUT955_Input/Output#I.2FO_Juggler|here]].
 
----
 
=====Actions tab=====
 
----
 
Navigate to '''Actions''' and '''create a new instance'''.
 
[[File:IO juggler action sms.png|border|center|class=tlt-border|1004x1004px]]
 
  
This will open a new configuration page:
+
Once finished, save the configuration by clicking [[File:Savenapply button.png|Savenapply button.png]].
[[File:IO_juggler_SMS_config_new.png|border|center|class=tlt-border|1004x1004px]]
 
  
# Type - '''SMS''';
+
===Scanning for available M-Bus devices===
# Text message - enter your '''Router 2 password''' and the '''SMS rule''' that you have created;
 
# Recipient's phone number - enter Router '''2 SIM cards number''';
 
# Save and apply changes
 
 
 
'''Note:''' Not marked fields can be left as default.
 
 
 
=====General tab=====
 
 
----
 
----
* Log into Router 2 WebUI;
 
* Go to the '''Services → I/O Juggler''' page;
 
* Open General tab ('''1''') and enable it ('''2''');
 
* Add new instance role ('''3''');
 
* Click Add ('''4''');
 
 
[[File:IO juggler general config.png|border|center|class=tlt-border|1004x1004px]]
 
 
After that, you will be prompted to edit an instance:
 
 
# Check '''Enable''';
 
# Trigger - '''Raising''';
 
# Add actions - Select the action you have created;
 
[[File:IO_Juggler_general_input_config.png|border|center|class=tlt-border|1004x1004px]]
 
  
==Via Public IP==
+
If you are not sure what address your M-Bus devices have, you can try scanning for the available M-Bus devices. To do so click on [[File:Scan button.png]] button.
For this configuration you will need a Static or Dynamic Public IP address. You can read up more on this in our article on [[Private_and_Public_IP_Addresses|Private and Public IP Addresses.]]
 
  
===RUT 1===
 
----
 
* Log into Router 1 WebUI;
 
* Go to the Services → Mobile Utilities → SMS Gateway page;
 
* Open '''Post/Get''' tab (1);
 
* Check '''enable''' (2);
 
* Enter desired '''username''' (3);
 
* '''Password''' (4);
 
* '''Confirm password''' (5);
 
* Save and apply changes (6);
 
[[File:Access control rutos.png|border|center|class=tlt-border|1004x1004px]]
 
  
[[File:SMS post get.png|border|center|class=tlt-border|1004x1004px]]
 
  
===RUT 2===
 
----
 
[[File:IO juggler script conf.png|border|center|class=tlt-border|1004x1004px]]
 
  
[[File:IO juggler general config.png|border|center|class=tlt-border|1004x1004px]]
+
==See Also==
  
[[File:IO_Juggler_general_input_config.png|border|center|class=tlt-border|1004x1004px]]
+
==External links==
 +
[https://flespi.io/#/ Flespi.io]

Latest revision as of 12:15, 24 July 2024

The information on this page is updated in accordance with the 00.07.4 firmware version .

Summary

This article contains instructions on how to send M-Bus data to the server using various protocols.

Configuration overview & prerequisites

Before we begin, let's take a look at the configuration that we are attempting to achieve and the prerequisites that make it possible.

Prerequisites:

  • TRB143;
  • M-Bus device;
  • Server;
  • An end device (PC, Laptop, Tablet, Smartphone) for configuration;


If you're having trouble finding this page or some of the parameters described here on your device's WebUI, you should turn on "Advanced WebUI" mode. You can do that by clicking the "Advanced" button, located at the top of the WebUI.

Networking rutos manual webui basic advanced mode 75.gif


Adding M-Bus devices

To add a new device to the configuration press Add Button.png button which is shown below.

Mbus adding new device.png

Device configuration


You will be granted to a new window. Configure your M-Bus device accordingly:

  1. Name: Enter the desired name of the M-Bus device
  2. Address type: select which M-Bus address will be used
  3. Primary/Secondary address: specify M-Bus address

Mbus adding new device configuration v3.png

Test if the M-Bus device is reachable by a specified primary/secondary address. To do so click on Ping device option mbus.png. You might get on of two outputs:

  • In case of correct M-Bus address, you will receive:

Mbus device pingable v2.png

  • In case of incorrect M-Bus address, you will receive:

Mbus device not pingable v2.png

Once finished, save the configuration by clicking Savenapply button.png.

Scanning for available M-Bus devices


If you are not sure what address your M-Bus devices have, you can try scanning for the available M-Bus devices. To do so click on Scan button.png button.