Domnev: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
<p style="color:red">The information in this page is updated in accordance with [https://wiki.teltonika-networks.com/view/FW_%26_SDK_Downloads'''00.07.03.4'''] firmware version .</p> | <p style="color:red">The information in this page is updated in accordance with [https://wiki.teltonika-networks.com/view/FW_%26_SDK_Downloads'''00.07.03.4'''] firmware version .</p> | ||
==Introduction== | ==Introduction== | ||
This article contains instructions on how to setup BACnet. | This article contains instructions on how to setup BACnet on Teltonika Networks devices. | ||
==Configuration overview and prerequisites== | ==Configuration overview and prerequisites== | ||
Line 9: | Line 9: | ||
'''Prerequisites''': | '''Prerequisites''': | ||
* RUT955; | * RUT955; | ||
* BACnet controller; | |||
* Server; | * Server; | ||
* An end device (PC, Laptop, Tablet, Smartphone) for configuration; | * An end device (PC, Laptop, Tablet, Smartphone) for configuration; | ||
Line 16: | Line 17: | ||
== BACnet == | == BACnet == | ||
BACnet is a communication protocol for building automation and control (BAC) networks that use the ASHRAE, ANSI, and ISO 16484-5 standards protocol | BACnet is a communication protocol for building automation and control (BAC) networks that use the ASHRAE, ANSI, and ISO 16484-5 standards protocol. | ||
'''Note''': It is a additional software that can be installed from the '''Services → [[RUT955_Package_Manager|Package Manager]]''' page. | |||
=== | === Configuration === | ||
---- | ---- | ||
Master - Slave Token Passing (MSTP) is most commonly used to connect field devices to controllers / routers / control applications. The physical layer uses RS485 which allows up to 128 devices to be installed on a single network. | Master - Slave Token Passing (MSTP) is most commonly used to connect field devices to controllers / routers / control applications. The physical layer uses RS485 which allows up to 128 devices to be installed on a single network. | ||
Line 32: | Line 31: | ||
=== Results === | === Results === | ||
---- | ---- | ||
== See also == | == See also == | ||
Line 37: | Line 38: | ||
== External links == | == External links == | ||
[https://sourceforge.net/projects/yetanotherbacnetexplorer/ Yabe] |
Revision as of 16:09, 27 February 2023
The information in this page is updated in accordance with 00.07.03.4 firmware version .
Introduction
This article contains instructions on how to setup BACnet on Teltonika Networks devices.
Configuration overview and prerequisites
Before we begin, let's take a look at the configuration that we are attempting to achieve and the prerequisites that make it possible.
Prerequisites:
- RUT955;
- BACnet controller;
- Server;
- An end device (PC, Laptop, Tablet, Smartphone) for configuration;
If you're having trouble finding any page or some of the parameters described here on your device's WebUI, you should turn on "Advanced WebUI" mode. You can do that by clicking the "Basic" button under "Mode," which is located at the top-right corner of the WebUI.
BACnet
BACnet is a communication protocol for building automation and control (BAC) networks that use the ASHRAE, ANSI, and ISO 16484-5 standards protocol.
Note: It is a additional software that can be installed from the Services → Package Manager page.
Configuration
Master - Slave Token Passing (MSTP) is most commonly used to connect field devices to controllers / routers / control applications. The physical layer uses RS485 which allows up to 128 devices to be installed on a single network.
Server
For the server, Yet Another BACnet Explorer is used
Results
See also
BACnet on RUT955