Averaged TSW030 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
26
0.23
Idle (12 V)
20
0.24
Idle (24 V)
11
0.26
Idle (44 V)
7
0.31
Idle (50 V)
6
0.3
Idle (57 V)
6
0.34


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
48
0.43
2 LAN devices connected + heavy data traffic1 (12 V)
38
0.46
2 LAN devices connected + heavy data traffic1 (24 V)
20
0.48
2 LAN devices connected + heavy data traffic1 (44 V)
12
0.53
2 LAN devices connected + heavy data traffic1 (50 V)
11
0.55
2 LAN devices connected + heavy data traffic1 (57 V)
10
0.57


Test type
Current (mA)
Power consumption (W)
8 LAN devices connected + heavy data traffic1 (9 V)
114
1.03
8 LAN devices connected + heavy data traffic1 (12 V)
88
1.06
8 LAN devices connected + heavy data traffic1 (24 V)
46
1.1
8 LAN devices connected + heavy data traffic1 (44 V)
28
1.23
8 LAN devices connected + heavy data traffic1 (50 V)
25
1.25
8 LAN devices connected + heavy data traffic1 (57 V)
22
1.25


1 - Data streams between devices were created using iPerf.
Power consumption may differ due to connected devices, testing environment and conditions.