Template:Networking rut2xx manual modbus modbus tcp table: Difference between revisions
Appearance
No edit summary |
No edit summary |
||
| Line 1: | Line 1: | ||
<table class="nd-mantable"> | <table class="nd-mantable"> | ||
<tr> | <tr> | ||
<th> | <th>Field</th> | ||
<th> | <th>Value</th> | ||
<th> | <th>Description</th> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Enable</td> | <td>Enable</td> | ||
<td>yes | no; | <td>yes | no; default: <b>none</b></td> | ||
<td> | <td>Turns Modbus TCP on or off.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Port</td> | <td>Port</td> | ||
<td>integer [0..65535]; | <td>integer [0..65535]; default: <b>none</b></td> | ||
<td> | <td>TCP port used for Modbus communications.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Allow Remote Access</td> | <td>Allow Remote Access</td> | ||
<td>yes | no; | <td>yes | no; default: <b>no</b></td> | ||
<td>Allows remote Modbus connections by adding an exception to the device's firewall on the port specified in the field above</td> | <td>Allows remote Modbus connections by adding an exception to the device's firewall on the port specified in the field above.</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Mobile Traffic Usage Logging</td> | <td>Mobile Traffic Usage Logging</td> | ||
<td>yes | no; | <td>yes | no; default: <b>no</b></td> | ||
<td>Enables Mobile Traffic Usage Logging (can also be enabled from <b>Status → Mobile Traffic → [[{{{name}}}_Mobile_Traffic#Configuration|Configuration]]</b>). <br> This is required in order to read mobile data usage information from Modbus registers</td> | <td>Enables Mobile Traffic Usage Logging (can also be enabled from <b>Status → Mobile Traffic → [[{{{name}}}_Mobile_Traffic#Configuration|Configuration]]</b>). <br> This is required in order to read mobile data usage information from Modbus registers.</td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
Latest revision as of 11:51, 23 July 2019
| Field | Value | Description |
|---|---|---|
| Enable | yes | no; default: none | Turns Modbus TCP on or off. |
| Port | integer [0..65535]; default: none | TCP port used for Modbus communications. |
| Allow Remote Access | yes | no; default: no | Allows remote Modbus connections by adding an exception to the device's firewall on the port specified in the field above. |
| Mobile Traffic Usage Logging | yes | no; default: no | Enables Mobile Traffic Usage Logging (can also be enabled from Status → Mobile Traffic → [[{{{name}}}_Mobile_Traffic#Configuration|Configuration]]). This is required in order to read mobile data usage information from Modbus registers. |