Template:Networking rutos manual tr-069: Difference between revisions
Gytispieze (talk | contribs) No edit summary |
Gytispieze (talk | contribs) No edit summary |
||
Line 1: | Line 1: | ||
{{Template: Networking_rutos_manual_fw_disclosure | {{Template: Networking_rutos_manual_fw_disclosure | ||
| fw_version = {{{series}}}_R_00.07.01 | | fw_version = {{{series}}}{{#ifeq:{{{name}}}|RUT241|M|}}_R_00.07.01 | ||
| series = {{{series}}} | | series = {{{series}}} | ||
}} | }} | ||
{{#ifeq: {{{series}}} | RUT9 |<br><i><b>Note</b>: <b>[[{{{name}}} TR-069 (legacy WebUI)|click here]]</b> for the old style WebUI (FW version RUT9XX_R_00.06.08. | {{#ifeq: {{{series}}} | RUT9 |<br><i><b>Note</b>: <b>[[{{{name}}} TR-069 (legacy WebUI)|click here]]</b> for the old style WebUI (FW version RUT9XX_R_00.06.08.5 and earlier) user manual page.</i>|}} | ||
{{#ifeq: {{{series}}} | RUT2 |<br><i><b>Note</b>: <b>[[{{{name}}} TR-069 (legacy WebUI)|click here]]</b> for the old style WebUI (FW version RUT2XX_R_00.01.14. | {{#ifeq: {{{series}}} | RUT2 | | ||
{{#switch: {{{name}}} | |||
| RUT241 = | |||
| #default = | |||
<br><i><b>Note</b>: <b>[[{{{name}}} TR-069 (legacy WebUI)|click here]]</b> for the old style WebUI (FW version RUT2XX_R_00.01.14.4 and earlier) user manual page.</i>}} | |||
|}} | |||
__TOC__ | __TOC__ | ||
==Summary== | ==Summary== |
Revision as of 11:41, 6 October 2021
Template:Networking rutos manual fw disclosure
Summary
TR-069 (Technical Report 069) is an application layer protocol designed for management of equipment connected to a remote network.
This chapter of the user manual provides an overview of the UPnP page in {{{name}}} devices.
TR-069 is additional software that can be installed from the System → [[{{{name}}} Package Manager|Package Manager]] page.
TR-069 Client Configuration
Field | Value | Description |
---|---|---|
Enable | off | on; default: off | Turns TR-069 client on or off. |
Periodic enable | off | on; default: on | Turns periodic data transmissions to server on or off. |
Accept server request | off | on; default: off | When enabled the device accepts connection requests from servers. |
Sending interval | integer [60..9999999]; default: 100 | Periodic data transmission frequency (in seconds). |
Username | string; default: easycwmp | Username used for authentication to a TR-069 server. |
Password | string; default: easycwmp | Password used for authentication to a TR-069 server. |
URL | host | ip; default: http://192.168.1.110:8080/openacs/acs | IP address or hostname of a TR-069 server. |
Management via TR-069
TR-069 can be used to set or get values from RUT devices. Below is a list of commands used for device management via TR-069.
- R - read only;
- RW - read/write;
- string(64) - 64 bit string;
- string(256) - 256 bit string;
- unsignedInt - integer storing only positive values.
Device Information:
- DeviceInfo.Manufacturer - device manufacturer (e.g., Teltonika) R
- DeviceInfo.ProductClass - device model (e.g., {{{name}}}) R
- DeviceInfo.SerialNumber - device serial number (e.g., 1000111111) R
- DeviceInfo.UpTime - device uptime R;
Mobile Information:
- MobileInfo.ICCID - SIM ICCID R;
- MobileInfo.Operator - name of operator used R;
- MobileInfo.SentThisMonth - bytes sent this month R;
- MobileInfo.ReceivedThisMonth - bytes received this month R;