Summary

This article contains instructions on how to send M-Bus data to the server using various protocols.

Configuration overview & prerequisites

Before we begin, let's take a look at the configuration that we are attempting to achieve and the prerequisites that make it possible.

Prerequisites:

  • TRB143;
  • M-Bus device;
  • Server;
  • An end device (PC, Laptop, Tablet, Smartphone) for configuration;


If you're having trouble finding this page or some of the parameters described here on your device's WebUI, you should turn on "Advanced WebUI" mode. You can do that by clicking the "Advanced" button, located at the top of the WebUI.

Networking rutos manual webui basic advanced mode 75.gif


Adding M-Bus devices

To add a new device to the configuration press Add Button.png button which is shown below.

Mbus adding new device.png

Device configuration


You will be granted to a new window. Configure your M-Bus device accordingly:

  1. Name: Enter the desired name of the M-Bus device
  2. Address type: select which M-Bus address will be used
  3. Primary/Secondary address: specify M-Bus address

Mbus adding new device configuration v3.png

Test if the M-Bus device is reachable by a specified primary/secondary address. To do so click on Ping device option mbus.png. You might get on of two outputs:

  • In case of correct M-Bus address, you will receive:

Mbus device pingable v2.png

  • In case of incorrect M-Bus address, you will receive:

Mbus device not pingable v2.png

Once finished, save the configuration by clicking Savenapply button.png.

Scanning for available M-Bus devices


If you are not sure what address your M-Bus devices have, you can try scanning for the available M-Bus devices. To do so click on Scan button.png button.