Template:Webui services rs232 rs232 configuration modbus gateway table
FIELD NAME | VALUE | DESCRIPTION |
---|---|---|
Listening IP | ip; Default: 0.0.0.0 | IP address on which the Modbus gateway will wait for incoming connections |
Port | integer [0..65535]; Default: 502 | The port number used to listen for incoming connections |
Slave ID configuration | User defined | Obtained from TCP; Default: User defined | Specifies whether slave IDs are user defined or automatically obtained from TCP |
Slave ID/Permitted slave IDs | integer | range of integers | multiple integers; Default: 1/1-247 | Specifies the slave ID of range of permitted slave IDs. The way this field is named and its function depends on the value of the Slave ID configuration field. A range of IDs can be specified by placing a hyphen (-) between two integer numbers. For example, if you permitt slave IDs in the range of 10 to 20, you would specify it as: 10-20 You can also specify multiple values that are not connected in a range using commas (,). For example, to specify 6, 50 and 100 as permitted slave IDs, you would have to use: 6,50,100 |