Line 3: |
Line 3: |
| }} | | }} |
| __TOC__ | | __TOC__ |
| + | |
| + | ==2023.09.01: Product technical changes== |
| + | |
| + | Starting from 2023 Q3 BAT120 Uninterruptable Power Supply will be changed. |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! style="text-align: left; background: white;" colspan="3" | Change description |
| + | |- |
| + | | style="text-align: left; background: white;" | Change type |
| + | | style="text-align: left; background: white;" colspan="2" | LED Indicators, Faster Charging |
| + | |- |
| + | | style="width: 221px; text-align: left; background: white;" | Detailed description |
| + | | style="width: 908px; text-align: left; background: white;" | The updated BAT120 will has several updated specifications, including enhancements to the LED indicators and an increase in battery charge current, resulting in improved charging for the device. |
| + | |
| + | The LED indicators will now provide updated information: |
| + | *IN PWR LED (Green): When the PSU is connected to the IN PWR socket, the LED will turn green, indicating that the battery is actively charging. |
| + | *IN PWR LED (Red): If the PSU is connected to the IN PWR socket but there is a charge failure or the input voltage (Vin) is too low, the LED will turn red, alerting you to the issue. |
| + | *OUT PWR LED (Green): When an external device is being powered through the OUT PWR socket, the LED will illuminate in green, ensuring you know that the output power is available. |
| + | *OUT PWR LED (Red): If the OUTPUT is shorted (requiring a reset) or the BAT120 has overheated (no reset needed), the OUT PWR LED will turn red, signifying an issue that needs attention. |
| + | *POWER LEDs (Blinking every 5 seconds): We have implemented a state-of-charge indicator for the battery. The POWER LEDs will now blink every 5 seconds, with each LED representing 25% of the battery's charge. |
| + | |- |
| + | | style="text-align: left; background: white;" | Change reasons |
| + | | style="text-align: left; background: white;" | Improved LED indicators and enhanced battery charging for better user experience |
| + | |- |
| + | |} |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! style="text-align: left; background: white;" colspan="3" | Affected products information |
| + | |- |
| + | | style="width: 221px; text-align: left; background: white;" | Model |
| + | | style="width: 448px; text-align: left; background: white;" | Affected order codes |
| + | | style="width: 448px; text-align: left; background: white;" | Order code changes |
| + | |- |
| + | | style="text-align: left; background: white;" | BAT120 |
| + | | style="text-align: left; background: white;" | BAT120 ***** |
| + | | style="text-align: left; background: white;" | No changes |
| + | |- |
| + | | style="text-align: left; background: white;" | Upcoming change date |
| + | | style="text-align: left; background: white;" colspan="2" | 2023 Q3 |
| + | |- |
| + | |} |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! style="text-align: left; background: white;" colspan="3" | Change impact |
| + | |- |
| + | | style="width: 221px; text-align: left; background: white;" | Risk assessment |
| + | | style="width: 908px; text-align: left; background: white;" colspan="2"| The product handling and storage process may require review. Marketing materials, such as photos, might need replacement. |
| + | |- |
| + | | style="text-align: left; background: white;" | Suggested implementation plan |
| + | | style="text-align: left; background: white;" colspan="2"| Information included in this PCN will help adapt to the upcoming changes. For more detailed information please contact your sales representative. |
| + | |- |
| + | |} |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! style="width: 1141px; text-align: left; background: white;" colspan="3" | Acknowledgement of PCN receipt |
| + | |- |
| + | | style="text-align: left; background: white;" colspan="3"| If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above |
| + | |- |
| + | |} |
| + | |
| + | To download the pdf version of this notification, [[Media:PCN_BAT120_2023_09_01_EN_TECHNICAL CHANGES.pdf|click here]]. |
| | | |
| ==2023.05.24: QSG flyer replacement== | | ==2023.05.24: QSG flyer replacement== |